We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
| Wavelength range | 200 - 850 nm |
| Path length | 1 mm, 2 mm, 5 mm, 10 mm |
| Wavelength accuracy | ± 1 nm |
| Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
| Wavelength range | 200 - 800 nm |
| Path length | 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary) |
| Wavelength accuracy | ± 1 nm |
| Wavelength Resolution | ≤ 3 nm (FWHM at Hg 546 nm) |
| Wavelength range | 230 nm, 260 nm, 280 nm |
| Path length | 1.0 mm, 0.2 mm |
| Minimum Sample size | 0.3 - 2.0 µl |
| Absorbance range | 0.2 - 75A (10 mm equivalent absorbance) |
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
| Wavelength range | 180 - 900 nm |
| Spectral Bandwidth | 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting) |
| Wavelength accuracy | ≤ 0.15 nm |
| Wavelength repeatability | ± 0.1 nm |
| Wavelength range | 190 - 900 nm |
| Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
| Wavelength accuracy | ≤ ± 0.5 nm |
| Wavelength repeatability | ≤ 0.3 nm(single direction) |
| Working spectral range | 190 to 900 nm |
| Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
| Wavelength accuracy | ± 0.15 nm |
| Wavelength repeatability | ≤ 0.04 nm |
| Wavelength Range | 900 nm to 2500 nm |
| Wavelength Accuracy | ≤ 0.2 |
| Wavelength Reproducibility | ≤ 0.05 |
| Bandwidth | 8 nm |
Labtron provides extensive range of visible spectrophotometer LVS series which can operate over a wavelength range of 320-1100nm. It brings unmatched performance with outstanding accuracy and precision.
| Wavelength Range | 325 ~ 1000 nm |
| Setting Wavelength | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ± 1.0 nm |
| Wavelength Range | 335 ~ 1000 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ± 2 nm |
| Wavelength Repeatability | 1 nm |
| Wavelength Range | 330 to 1000 nm |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ± 2 nm |
| Wavelength Repeatability | ≤ 1.0 nm |
| Wavelength Range | 400 nm to 700 nm |
| Wavelength Interval | 10 nm |
| Sensor | High sensitivity silicon photodiode |
| Light Source | LED |
| Wavelength Range | 360 nm to 780 nm |
| Wavelength Pitch | 10 nm |
| Sensor | Silicon Photodiode Array |
| Grating Method | Concave Grating |
| Illumination system | d/8 (Diffused lighting, 8° observation angle)<br/> SCS optical engine (light splitting and integration system)<br/> ETC (real time calibration technology )<br/> SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
| Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
| Illumination light source | CLED |
| Sensor | Dual light path sensor array |