Benchtop conductivity meter LBCM-A11

Benchtop conductivity meter LBCM-A11 is easy to use, it comes with 1 - 3 point calibration system for automatic recognition of the known calibration standards. The LCD display helps to view the measurements and set parameters. The temperature calibration by manual method improves the accuracy of conductivity meter. The system of conductivity meter can set up to 6 parameters like number of calibration points, cell constant etc.

Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1
Conductivity calibration solutions 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Conductivity calibration points 1 - 3 points
Temperature compensation range & mode Manual or automatic, 0 to 100 °C , 32 to 212 °F
Temperature range 0 to 105 °C, 32 to 221 °F
Temperature accuracy ± 1°
Temperature resolution 0.1 °C
Temperature coefficient 0.0 to 10.0 % per °C
Cell constant K= 0.1, 1, 10 or User-defined
Data hold function Manual or automatic
Connector 6 - pin mini plug
Display LCD (315 × 75 mm)
Power DC 6 V / 400 mA power adapter, AC 220 V / 50Hz
Dimension (L × W × H) 210 × 205 × 75 mm
Weight 1.5 kg
  • Equipped with white backlit LCD display
  • 1 - 3 point calibration with automatic recognition of calibration solution
  • Manual temperature compensation improves the measurement accuracy of meter
  • Automatic temperature compensation for accurate measured value over the entire range
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Reset function automatically resumes all the settings to default mode
  • System menu allows setting the 6 parameters
  • Automatic power off helps to reduce battery power consumption
  • Help message as an operational guide for Quick access to the conductivity meter
Conductivity electrode for pure water
Conductivity electrode for general liquids
Conductivity electrode for high conductivity
Conductivity standard solution 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm

The benchtop conductivity meter is used in water quality analysis, research, education, environmental monitoring, chemicals & liquids quality testing etc. for measuring conductivity.

Related Products of Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L
Salinity measurement range 0.00 to 8.00 %
Conductivity Mode
Conductivity measurement range 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity accuracy ±1% F.S.
Conductivity resolution 0.001, 0.01, 0.1, 1
Conductivity calibration points 1 to 3 points
Conductivity calibration solutions 10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
TDS Mode
TDS measurement Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.01 to 1.00 (default 0.5)
TDS Calibration points 3 points
Temperature Mode
Temperature range 0 to 105°C, 32 to 221°F
Temperature accuracy ±1°C
Temperature resolution 0.1°C, 0.1°F
Temperature calibration points 1 point
Temperature Compensation Range and Mode Manual or Automatic, 0 to 100°C , 32 to 212°F
Temperature coefficient 0.0 to 10.0 % per °C
Cell constant K=0.1, 1, 10
Determination range
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error Less or less than 10 %
Sample container/ bottle quantity 1 to 6
Sample container/ bottle Capacity 1000 ml

pH Meters (Portable)

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

pH range (-2.00) to 20.00 pH
pH accuracy ± 0.002 pH
pH resolution 0.1, 0.01, 0.001 pH
Calibration points 1 - 5 points
pH range (-2.00) to 16.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 2 points
pH measurement range 01.00 to 15.00 pH
pH calibration points 1 to 3 points
pH Buffer Solutions USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
pH accuracy ± 0.01 pH
COD
COD determination range 5 to 5000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen
Ammonia nitrogen determination range 0.02 to 30 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch 20 pcs
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous
Total phosphorous determination range 0.002 to 10 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette
COD
COD determination range 2 to 10000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen
Ammonia nitrogen determination range 0.02 to 60 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous
Total phosphorous determination range 0.002 to 20 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Water hardness range 0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L