Multi purpose Pocket pH tester LPPT-B10

The multipurpose pocket pH tester LPPM-B10 comes with BNC connector, it can be connected to different pH electrode for different applications. With (-1.00) to 15.00 pH measurement range, 1 - 3 points calibration system and manual temperature compensation mode, this multi-purpose pocket pH tester can measure pH , temperature over wide range with accuracy. Its built–in system menu can customize five functional parameters as per requirement.

pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Different electrodes can be connceted via BNC Connector
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
Calibration solution USA (pH 4.0/7.00/10.01)
Operating temperature
Temperature accuracy
Temperature compensation range 0 °C to 100 °C , Manual
Data hold function Manual or Automatic
Connector BNC
Shutdown mode
Dimension (length × diameter) 175 × 40 mm
Weight 100 g
Power type 2 × 1.5 V AAA batteries
Battery life About 200 hours
  • 1 - 3 point calibration , automatic identification of calibration buffers
  • Manual mode for temperature compensation ensures high precision measurement results
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Automatic power off to reduce battery power consumption
  • Reset function automatically resumes all the setting back to factory default options
  • Alarm icon to indicate low battery
  • Built-in system menu, customizable
  • Reset function to restore settings to default mode
  • Waterproof performance to maintain integrity of the instrument
pH electrodes to measure pH of liquids and semi-solids , solvents
pH standard buffer USA (pH 4.01/7.00/10.01), NIST (pH 4.01/6.86/9.18)

The multipurpose pocket pH tester can be used in water and waste water analysis, aquaculture & environmental monitoring, food & beverage industry & other indusries.

Related Products of pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

pH measurement range 0.0 - 14.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
Calibration points 1 - 2 points
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points
COD
COD determination range 5 to 5000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen
Ammonia nitrogen determination range 0.02 to 30 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch 20 pcs
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous
Total phosphorous determination range 0.002 to 10 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette
COD
COD determination range 2 to 10000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen
Ammonia nitrogen determination range 0.02 to 60 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous
Total phosphorous determination range 0.002 to 20 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range 0 to 19999 ppm, mg/L, mol/L
Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
Ion calibration points 2 - 5 points
Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range
Ion accuracy
Ion calibration points
Ion calibration solutions
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
TDS measurement
TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy ± 1 % F.S.
TDS factor 0.1 - 1.0 (default 0.5)
Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
TDS
TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS accuracy ±1 % F.S
TDS factor 0.01 to 1.00 (Default 0.5)
TDS resolution 0.01, 0.1, 1
Temperature
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 3 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
Temperature
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient Linear
Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
Salinity
Salinity range 0.00 to 80.00 ppt, 0.00 to 42.00 psu
Salinity accuracy ±1% F.S
Salinity measurement modes Practical Salinity (psu) or Natural Seawater (ppt)
Salinity resolution 0.01, 0.1, 1
Temperature
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
Dissolved Oxygen Mode
Dissolved Oxygen Range 0.00 to 20.00 mg/ L
Dissolved Oxygen Accuracy ± 0.2 mg/ L
Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
Dissolved Oxygen Calibration Points 1 or 2 Points
% Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 to 50 g/ L
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)