| pH Mode |
| pH range |
-2.00 to 20.00 pH |
| pH Accuracy |
± 0.002 pH |
| pH Resolution |
0.1/0.01/0.001 pH, selectable |
| pH Calibration Points |
1 to 5 Points |
| pH Buffer Solutions |
USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
|
| ORP Mode |
|
| mV Mode |
| mV Range |
-1999.9 to 1999.9 mV |
| mV Accuracy |
± 0.2 mV |
| mV Resolution |
0.1/1 mV, selectable |
| mV Calibration Points |
1 Point |
|
| Ion Mode |
|
| Water Hardness Mode |
|
| Temperature Mode |
|
| Conductivity Mode |
| Conductivity Range |
0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm |
| Conductivity Accuracy |
± 0.5% F.S. |
| Conductivity Resolution |
0.01/0.1/1 |
| Conductivity Calibration Points |
1 to 5 Points |
| Conductivity Solutions |
10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm |
| Conductivity Temperature coefficient |
0.0 to 10.0 %/°C |
| Compensation mode |
Linear or Pure Water |
| Cell Constant |
K=0.1, 1, 10 or Custom |
| Reference temperature |
20 or 25°C |
|
| TDS Mode |
| TDS Range |
0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
| TDS Accuracy |
± 1 % F.S. |
| TDS Factor |
0.1 to 1.0 (default 0.5) |
|
| Salinity Mode |
|
| Resistivity Mode |
|
| Dissolved Oxygen Mode |
|
| Temperature Range |
0 to 105°C, 32 to 221°F |
| Temperature Accuracy |
± 0.5°C |
| Temperature Resolution |
0.1°C |
| Temperature Calibrations Points |
1 Point |
| Temperature Compensation Mode |
Manual or Automatic |
| Data Hold Function |
Manual or Automatic Endpoint Detection |
| Stability Criteria |
Low or High |
| Calibration Due Alarm |
1 to 31 Days |
| Reset Function |
Yes |
| Memory |
Stores Up to 500 data sets |
| Output |
USB interface |
| Connector |
BNC, 6-pin mini plug |
| Display |
LCD |
| Power supply |
DC5 V, AC 220 V, 50 Hz |
| Dimension (L × W × H) |
210 × 188 × 60 mm |
| Weight |
1.5 kg |
- Common Features
- Stability indicator displays the status of current measurement
- Auto hold function freezes stable, final readings for better viewing and recording
- Manual temperature calibration to rectify the deviations in temperature
- Automatic temperature compensation for accurate measured value over the entire range
- Selectable temperature units (°C or °F) for different application requirements
- Expanded memory stores and recalls up to 500 readings
- Help message as an operational guide, helps users for quick access to the parameters
- Reset function automatically resumes all the setting back to factory default options
- Store data is transferrable into computer via USB communication interface
- pH mode
- 1-5 points push button calibration to automatically identify pH buffer
- Convenient to select pH buffer standard (USA/NIST/DIN) or custom
- Automatic electrode slope display helps operator whether to replace the sensor
- Conductivity/TDS mode
- 1-5 point for calibration with automatically identification of calibration solutions
- Can select cell constant (0.1/1/10) and normalization temperature (20°C or 25°C)
- TDS conversion factor, seawater, practical salinity measurements mode to meet different water quality measurement requirements
- Linear or pure water compensation improves the measurement accuracy
| Accessories No. |
Name |
| 1 |
Temperature probe |
| 2 |
Calibration Solutions for pH and Conductivity |
| 3 |
pH electrodes suitable for non-aqueous, high alkalinity, low conductivity, tis buffers, biofuels and others |
| 4 |
Conductivity electrode suitable for Pure water, general applications, high conductivity liquids |
| 5 |
DC5V power adapter |
Used for quality checking of water on different parameters across research, QC labs, water management plants and others production units.