COD |
- COD determination range: 5 to 5000 mg/ L
- COD measurement accuracy: COD < 50 mg/ L, ≤ ± 10 %
and
COD > 50 mg/ L, ≤ ± 5 %
- COD minimum detection limit: 0.1 mg/ L
- COD measurement time: 20 minutes
- COD repeatability: ≤ ± 5 %
- Processing sample number per batch: 12 pcs
- Consumables for colorimetric COD measurement: Colorimetric tubes and Cuvette
- COD reactor digestion temperature: 165 ± 0.5°C
- COD reactor digestion time: 10 min
- COD reactor time setting switches: 3 pcs
- Anti-chlorine interference: (Cl) < 1000 mg/ L No effect
|
Ammonia nitrogen |
- Ammonia nitrogen determination range: 0.02 to 30 mg/ L
- Ammonia nitrogen measurement accuracy: ≤ ± 10 %
- Ammonia nitrogen minimum detection limit: 0.01 mg/ L
- Ammonia nitrogen measurement time: 10 to 15 minutes
- Ammonia nitrogen repeatability: ≤ ± 5 %
- Processing sample number per batch: 20 pcs
- Consumables for colorimetric ammonia nitrogen measurement: Colorimetric tubes and Cuvette
- Ammonia nitrogen reactor time setting switches: 3 pcs
|
Total phosphorous |
- Total phosphorous determination range: 0.002 to 10 mg/ L
- Total phosphorous total phosphorous measurement accuracy: ≤ ± 5 %
- Total phosphorous minimum detection limit: 0.001 mg/ L
- Total phosphorous measurement time: 35 to 50 minutes
- Total phosphorous repeatability: ≤ ± 5 %
- Processing sample number per batch: 12 pcs
- Consumables for colorimetric total phosphorous measurement: Colorimetric tubes and Cuvette
- Total phosphorous reactor digestion temperature: 120 ± 0.5°C
- Total phosphorous reactor digestion time: 30 min
- Total phosphorous reactor time setting switches: 3 pcs
|
Turbidity |
- Turbidity determination range: 0.5 to 400 NTU
- Turbidity measurement accuracy: ≤ ± 5 %
- Turbidity minimum detection limit: 0.1 NTU
- Turbidity measurement time: 1 minute
- Turbidity repeatability: ≤ ± 5 %
- Consumables for colorimetric turbidity measurement: Colorimetric Cuvette
|
Light source life |
100000 hours |
Optical stability |
≤ 0.001 A/ 10 min |
No. of curves |
56 |
Storage data |
12000 |
Display |
LCD (320 × 240) |
Interface |
USB |
Power supply |
AC 200 V |
Dimension |
450 × 300 × 250 mm |
Gross Weight |
18 kg |
- Benchtop design
- High definition LCD screen with detailed user interface
- Includes colorimetric, digestive system, timing system functions
- Intelligent data analysis
- USB infrared data communication
- Built-in mini printer
- High accuracy measurement readings
- User-friendly operation
Used in water quality testing based on COD, ammonia nitrogen, total phosphorous and turbidity parameters across plants, laboratories, and industries.