Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.
Sensor type | Platinum sensor |
Connector | 6 pin |
ORP measurement range | (-999) to 999 mV |
ORP accuracy | ± 2 mV |
Connector | BNC |
ORP measurement range | (-999) to 999 mV |
ORP accuracy | ± 2 mV |
ORP resolution | 1 mV |
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
||||||||||||||||||
Dissolved Oxygen Mode |
|
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
||||||||||||||||||
TDS Mode |
|
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
||||||||||||||||||
TDS Mode |
|
Conductivity |
|
||||||||||
Salinity |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
Conductivity |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic | ||||||||||
Temperature coefficient | Linear |
Conductivity |
|
||||||||||
TDS |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.
Dissolved oxygen range | 0.0 to 20.0 mg/L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg/L |
% of saturation of oxygen | 0.0 to 200.0% |
Sensor type | Polarographic dissolved oxygen probe |
Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Resolution | 0.1 mg / L |
Calibration points | 1 - 2 points |
Dissolved oxygen range | 0.0 - 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.2 mg / L |
Resolution | 0.01 mg / L |