Portable Dissolved oxygen meter LPRDO-A10

Portable Dissolved oxygen meter LPRDO-A10 is equipped with polarographic sensor to measure the dissolved oxygen content. The manual salinity & barometric pressure compensation helps in accurate measurement of dissolved oxygen. It can store up to 48 sets of data & it is transferrable to PC via USB interface. Due to its portable nature this meter can be used across water purification plants, waste water management plants for testing & quality analysis.

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points
Sensor type Polarographic DO probe
Temperature compensation range 0 to 40 °C, 32 °F to 104 °F
Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 - 35 g / L
% of saturation of oxygen range 0.0 to 200.0 %
% of saturation of oxygen accuracy ± 10 % F.S.
% of saturation of oxygen resolution 0.001
System menu
Data hold function Manual
Power off
Reset function Yes
Memory Stores up to 48 sets of data
Output USB communication interface
Display LCD screen
Connector 4-pin mini plug
Calibration due
Stability connector
Battery life Approximately 150 hours
Power 1 x 9 V / 800 mA battery
Dimension (L x W x H) 185 × 88 × 32 mm
Weight 300 g
  • Equipped with polarographic sensor & LCD display
  • 1-2 points calibration using air saturated water & zero oxygen solution
  • Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen
  • Stores up to 48 sets of data
  • Data is transferrable to PC via USB interface
  • Built-in real time clock stamps stores data to meet GLP standard
  • Automatic temperature compensation for accurate measured value over the entire range
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Reset function automatically resumes all the settings to default mode
  • Help message as an operational guide for quick beginning to the dissolved oxygen meter
Polarographic sensor
30 mL electrolyte solution per bottle
Membrane cap

Portable dissolved oxygen meter has applications in water & waste water management industry, environmental monitoring, surface ground water, research & development, education to detect content of dissolved oxygen.

Related Products of Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Dissolved oxygen range 0.0 - 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
Calibration points 1 - 2 points

ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Sensor type Platinum sensor
Connector 6 pin
ORP measurement range (-999) to 999 mV
ORP accuracy ± 2 mV
Connector BNC
ORP measurement range (-999) to 999 mV
ORP accuracy ± 2 mV
ORP resolution 1 mV
Range 0 to 1.0 aw
Resolution 0 to 1.0 aw
Accuracy ± 0.02 aw
Sensor Nonconductive humidity sensor
Measuring range Water activity 0 to 0.980 aw (no condensing )
Temperature range 0 to 50°C
Measurement accuracy ± 0.015 aw
Temperature accuracy ± 0.5°C
Measurement range 20000 mg/L <br/> 0.01 mg/L ~ 45000 mg/L <br/> 0.01 mg/L ~ 120000 mg/L
Measurement accuracy ± 2 % F.S. of its range ( Depending on the homogeneity of sludge)
Pressure range ≤ 0.4 Mpa
Flow rate ≤ 2.5 m/s, 8.2 ft./s
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen Calibration points 1 - 2 points
Dissolved oxygen accuracy ± 0.5 mg / L
Dissolved oxygen resolution 0.1 mg / L
COD
COD determination range 2 to 10000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen
Ammonia nitrogen determination range 0.02 to 60 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous
Total phosphorous determination range 0.002 to 20 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette
COD
COD determination range 5 to 5000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen
Ammonia nitrogen determination range 0.02 to 30 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch 20 pcs
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous
Total phosphorous determination range 0.002 to 10 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette