Bench top Turbidity Meter (with built-in printer) LTM-C12

Bench top turbidity meter (with built-in printer) LTM-C12 comes with microprocessor controlled system, works on 90° scattered light principle to measure water turbidity in nephelometric turbidity unit i.e. NTU. The formazine standard solution of turbidity mentioned in ISO 7027 is used for turbidity analysis. This turbidity meter delivers highly accurate results with better numerical calculations to meet GLP standards.

Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) 0.001
Calibration point 4
Sample volume 18 to 20 ml
Principle method 90° scattered light
Operating temperature Room Temperature
Working temperature Room Temperature
Light source Infrared-emitting diode (850 nm λ)
Detector Silicon photodiode
Error value (F.S) ±2%, ±3%,±5% 
Zero drift (F.S) ±0.5% (0.02 NTU)
Reset functions No
Memory Nil
Output RS232 data communication interface
Dimension 415 × 375 × 200 mm
Weight 4 kg
Power batteries DC 1.5 V, 5 AA alkaline batteries
Power supply AC 220 V, 50 Hz
  • Equipped with Built-in printer
  • Touch keypad backlight LCD display
  • Wide turbidity measurement range
  • High through put stability
  • Quick and automatic multi-points calibration
  • Auto power off function
  • Easy to operate

Used in water treatment plants, swimming pool, water recycling units, research and quality testing laboratories of pharmacy, life science, food, and beverage industry.

Measuring range (NTU) 0 to 100, 100 to 400
Minimum readout value (NTU) 0.01, 0.1
Calibration point 5
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) 0.01
Calibration point 3
Sample volume 18 to 20 ml
Light source LED/860 nm (Wavelength)
Readings display LCD
Unit switches NTU, FTU, EBC, ASBC
Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 3
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 100 to 800
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
Minimum readout value (NTU) 0.01, 0.1
Calibration point 5
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01
Calibration point 2
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100, 100 to 1000
Minimum readout value (NTU) 0.01, 0.1
Calibration point 7
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100
Minimum readout value (NTU) 0.001
Calibration point 2
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) 0.001
Calibration point 5
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) 0.01
Calibration point 5
Sample volume 18 to 20 ml
pH measurement range 01.00 to 15.00 pH
pH calibration points 1 to 3 points
pH Buffer Solutions USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
pH accuracy ± 0.01 pH
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm
Conductivity calibration points 1 to 3 points
Conductivity accuracy ±1 % F.S.
Conductivity resolution 0.001/ 0.01/ 0.1/ 1

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Conductivity measurement range 10 to 1999 µS/cm
Type of conductivity Mid-range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 1.0 to 199.9 µS/cm
Type of conductivity Low range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 0.1 to 19.99 mS/cm
Type of conductivity High range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Dissolved oxygen range 0.0 - 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
Calibration points 1 - 2 points
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Water hardness range 0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L