Bench top Turbidity Meter (with built-in printer) LTM-C12

Bench top turbidity meter (with built-in printer) LTM-C12 comes with microprocessor controlled system, works on 90° scattered light principle to measure water turbidity in nephelometric turbidity unit i.e. NTU. The formazine standard solution of turbidity mentioned in ISO 7027 is used for turbidity analysis. This turbidity meter delivers highly accurate results with better numerical calculations to meet GLP standards.

Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) 0.001
Calibration point 4
Sample volume 18 to 20 ml
Principle method 90° scattered light
Operating temperature Room Temperature
Working temperature Room Temperature
Light source Infrared-emitting diode (850 nm λ)
Detector Silicon photodiode
Error value (F.S) ±2%, ±3%,±5% 
Zero drift (F.S) ±0.5% (0.02 NTU)
Reset functions No
Memory Nil
Output RS232 data communication interface
Dimension 415 × 375 × 200 mm
Weight 4 kg
Power batteries DC 1.5 V, 5 AA alkaline batteries
Power supply AC 220 V, 50 Hz
  • Equipped with Built-in printer
  • Touch keypad backlight LCD display
  • Wide turbidity measurement range
  • High through put stability
  • Quick and automatic multi-points calibration
  • Auto power off function
  • Easy to operate

Used in water treatment plants, swimming pool, water recycling units, research and quality testing laboratories of pharmacy, life science, food, and beverage industry.

Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 3
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 100 to 800
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
Minimum readout value (NTU) 0.01, 0.1
Calibration point 5
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 100 to 500
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 100 to 400
Minimum readout value (NTU) 0.01, 0.1
Calibration point 5
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01
Calibration point 2
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100
Minimum readout value (NTU) 0.01, 0.1
Calibration point 1
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100
Minimum readout value (NTU) 0.001
Calibration point 2
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100, 100 to 1000
Minimum readout value (NTU) 0.01, 0.1
Calibration point 7
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) 0.01
Calibration point 5
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) 0.001
Calibration point 5
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Light source LED/860 nm (Wavelength)
Readings display LCD
Unit switches NTU, FTU, EBC, ASBC
Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU
Determination range
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error Less or less than 10 %
Sample container/ bottle quantity 1 to 6
Sample container/ bottle Capacity 1000 ml

pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

pH measurement range 0.0 - 14.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Ion measurement range Cl range: 5 × 10<sup>6</sup> - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Ion measurement range Na range: 1 × 10<sup>5</sup> - 1 M, 0.1 - 23000 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Ion measurement range F range: 1 × 10<sup>6</sup>M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
pH measurement range 01.00 to 15.00 pH
pH calibration points 1 to 3 points
pH Buffer Solutions USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
pH accuracy ± 0.01 pH
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen Calibration points 1 - 2 points
Dissolved oxygen accuracy ± 0.5 mg / L
Dissolved oxygen resolution 0.1 mg / L