Benchtop pH meter LBPM-A11

Benchtop pH meter LBPM-A11 comes with 0.0 to 14.00 pH range is suitable for daily measurements, testing. Automatic calibration can be performed at 2 points using standard USA or NIST pH buffers. It offers automatic or manual temperature compensation of pH measurements. The pH meter with sleek design has easy to read backlit LCD screen that display pH measurements & temperature simultaneously.

pH measurement range 0.00 to 14.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 2 points
Calibration solutions USA (pH 4.0/7.00/10.01)
ORP measurement range
ORP accuracy
ORP calibration points
ORP calibration range
ORP calibration solutions
Temperature compensation 0 to 100°C
Compensation mode Manual or automatic
mV range -1999 to 1999 mV
mV accuracy ±1mV
mV resolution 1 mV
Temperature range 0 to 100°C, 32 to 212°F
Temperature accuracy ±1°C
Stability conditions
Calibration due
memory
Output
Temperature resolution 1°C
Hold function
Power off
Reset function
Connector BNC
Display LCD
Dimension (L*W*H) 210×205×65 mm
Weight 1.5 kg
Power DC9V, Ac adapter, AC220V /50Hz
  • Equipped with white backlit LCD display
  • pH measurement range 0.0 to 14.00 pH
  • 2 points calibration to automatically identify pH buffer
  • Automatic electrode slope display, helps the operator when to replace the sensor
  • Automatic temperature compensation for accurate measured value over the entire range
  • Universal BNC connector
  • Built-in solution holder
pH buffer solutions USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
Temperature sensor
pH probe for suitable measuring e.g. (pure water, liquids, semisolids substance

The benchtop pH meter can be used for daily measurement of pH & temperature at schools, colleges & research laboratories & water testing plants.

Related Products of pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Temperature compensation 0 to 100°C, 32°F to 212°F Manual or Automatic
Hold function Manual or automatic endpoint detection
Stability criteria Standard or High-accuracy
Interval readings 10, 30, 60 seconds, 10, 30 minutes or Off
pH measurement range -1.00 to 15.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 1-3 points
pH measurement range -2.000 to 20.000 pH
pH accuracy ± 0.002 pH
Calibration points 1-5 points
Calibration solutions USA, NIST, DIN or user defined

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range
Ion accuracy
Ion calibration points
Ion calibration solutions
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range 0 to 19999 ppm, mg/L, mol/L
Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
Ion calibration points 2 - 5 points
Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
TDS measurement
TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy ± 1 % F.S.
TDS factor 0.1 - 1.0 (default 0.5)

TDS Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

TDS range 5 - 1000 ppm
TDS accuracy ± 1 % F.S.
TDS factor 0.4 to 1.0 (default 0.5)
Calibration points 1 point
TDS range 0.5 - 100.0 ppm
TDS accuracy ± 1 % F.S.
TDS factor 0.4 to 1.0 (default 0.5)
Calibration points 1 point
TDS range 0.05 - 10.00 ppt
TDS accuracy ± 1 % F.S.
TDS factor 0.4 to 1.0 (default 0.5)
Calibration points 1 point
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Light source LED/860 nm (Wavelength)
Readings display LCD
Unit switches NTU, FTU, EBC, ASBC
Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU
Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

pH measurement range 0.00 to 14.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 2 points
pH measurement range -1.00 to 15.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 1-3 points
Temperature compensation 0 to 100°C, 32°F to 212°F Manual or Automatic
Hold function Manual or automatic endpoint detection
Stability criteria Standard or High-accuracy
Interval readings 10, 30, 60 seconds, 10, 30 minutes or Off
COD
COD determination range 2 to 10000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen
Ammonia nitrogen determination range 0.02 to 60 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous
Total phosphorous determination range 0.002 to 20 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette
COD
COD determination range 5 to 5000 mg/ L
COD measurement accuracy COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit 0.1 mg/ L
COD measurement time 20 minutes
COD repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric COD measurement Colorimetric tubes and Cuvette
COD reactor digestion temperature 165 ± 0.5°C
COD reactor digestion time 10 min
COD reactor time setting switches 3 pcs
Anti-chlorine interference (Cl) < 1000 mg/ L No effect
Ammonia nitrogen
Ammonia nitrogen determination range 0.02 to 30 mg/ L
Ammonia nitrogen measurement accuracy ≤ ± 10 %
Ammonia nitrogen minimum detection limit 0.01 mg/ L
Ammonia nitrogen measurement time 10 to 15 minutes
Ammonia nitrogen repeatability ≤ ± 5 %
Processing sample number per batch 20 pcs
Consumables for colorimetric ammonia nitrogen measurement Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches 3 pcs
Total phosphorous
Total phosphorous determination range 0.002 to 10 mg/ L
Total phosphorous total phosphorous measurement accuracy ≤ ± 5 %
Total phosphorous minimum detection limit 0.001 mg/ L
Total phosphorous measurement time 35 to 50 minutes
Total phosphorous repeatability ≤ ± 5 %
Processing sample number per batch 12 pcs
Consumables for colorimetric total phosphorous measurement Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature 120 ± 0.5°C
Total phosphorous reactor digestion time 30 min
Total phosphorous reactor time setting switches 3 pcs
Turbidity
Turbidity determination range 0.5 to 400 NTU
Turbidity measurement accuracy ≤ ± 5 %
Turbidity minimum detection limit 0.1 NTU
Turbidity measurement time 1 minute
Turbidity repeatability ≤ ± 5 %
Consumables for colorimetric turbidity measurement Colorimetric Cuvette