pH measurement range |
-2.000 to 20.000 pH |
pH accuracy |
± 0.002 pH |
pH resolution |
|
Calibration points |
1-5 points |
Calibration solutions |
USA, NIST, DIN or user defined |
ORP measurement range |
-1999.9 to 1999.9 mV |
ORP accuracy |
±0.2 mV |
ORP calibration points |
1 point |
ORP calibration range |
±200 mV |
ORP calibration solutions |
mV & relative mV |
Temperature compensation |
0 to 100°C, 32 to 212°F |
Compensation mode |
Manual or automatic |
mV range |
|
mV accuracy |
|
mV resolution |
|
Temperature range |
|
Temperature accuracy |
|
Stability conditions |
Low or high |
Calibration due |
0 to 31 days |
memory |
Stores up to 500 data sets |
Output |
USB communication interface |
Temperature resolution |
|
Hold function |
|
Power off |
|
Reset function |
|
Connector |
BNC |
Display |
LCD |
Dimension (L*W*H) |
210×188×60 mm |
Weight |
1.5 kg |
Power |
DC5V using AC adapter, AC220V /50 Hz |
- pH Mode Features:
- Equipped with white backlit LCD display
- pH measurement range -2.000 to 20.000 pH
- 1 to 5 points push button calibration to automatically identify pH buffer
- Automatic electrode slope display, helps the operator when to replace the sensor
- Automatic temperature compensation for accurate measured value over the entire range
- Universal BNC connector
- Built-in solution holder
- ORP Mode Features:
- ORP measurement range -1999.9 to 1999.9 mV
- Single point offset calibration to adjust the display value to a known standard
- Relative & absolute mV measurements for accurate ORP readings
- Common Features:
- Calibration due reminder informs operator to calibrate the meter regularly
- Stability indicator displays the status of current measurement
- Auto hold function freezes stable, final readings for better viewing and recording
- Manual temperature calibration to rectify the deviations in temperature
- Automatic temperature compensation for accurate measured value over the entire range
- Selectable temperature units (°C or °F) for different application requirements
- Expanded memory stores and recalls up to 500 readings
- Help message as an operational guide, helps users for quick access to the parameters
- Reset function automatically resumes all the setting back to factory default options
- Store data is transferrable into computer via USB communication interface
pH Electrode
pH buffer pouches (pH 4.01/6.98/9.18) NIST
pH buffer pouches (pH 4.01/7.00/10.01) USA
Temperature probe
The benchtop pH meter can be used for daily measurement of pH, ORP & temperature at schools, colleges & research laboratories & water testing plants.