Benchtop Water hardness meter LBWM-A10

Benchtop Water hardness meter LBWM-A10 is equipped with large backlit LCD display, 2 to 5 points calibration with low to high concentration range. The calibration due reminder alerts user for calibration of the meter on regular basis. The System menu allows setting the 7 parameters like stability condition, auto-power off etc. It measure salts of calcium & other elements at mg/L, mmol/ scale which causes hardness water.

Water hardness range 0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
Temperature range 0 - 105 °C
Temperature accuracy ± 0.5 °C
Calibration range Measured value ± 10 °C
Temperature compensation range 0 to 50 °C
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Memory Stores up to 500 sets of data
Output USB communication interface
Connector BNC
Power DC5V, using AC adapter, 220V/50Hz
Dimension (L × W × H) 170 × 85 × 30 mm
Weight 1.5 kg
  • Large LCD display
  • Two to five points calibration with low to high range
  • System menu with 7 parameters setting
  • Stability indicator to robotically display current measurements
  • Automatic electrode diagnosis shows the slope of sensor
  • Calibration due reminder for regular calibration of the meter
  • Manual temperature compensation for better measurement accuracy of meter
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Automatic temperature compensation for accurate measured value over the entire range
  • Reset function
  • Enlarged memory can store up to 500 sets of data
  • Built-in real time clock stamps
  • Operational guide for Quick access to the conductivity meter
Water hardness electrode range 0.00005 to 0.2 M

Benchtop water hardness meter is used in testing the hardness level of tap water, drinking water, filtered water, water used for different experiments and testing across food, textile, painting & other industries.

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Temperature compensation 0 to 100°C, 32°F to 212°F Manual or Automatic
Hold function Manual or automatic endpoint detection
Stability criteria Standard or High-accuracy
Interval readings 10, 30, 60 seconds, 10, 30 minutes or Off
pH measurement range -1.00 to 15.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 1-3 points
pH measurement range 0.00 to 14.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 2 points

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
Calibration points 1 - 2 points
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Conductivity measurement range 1.0 to 199.9 µS/cm
Type of conductivity Low range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 10 to 1999 µS/cm
Type of conductivity Mid-range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 0.1 to 19.99 mS/cm
Type of conductivity High range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Water hardness range 0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L

ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Sensor type Platinum sensor
Connector 6 pin
ORP measurement range (-999) to 999 mV
ORP accuracy ± 2 mV
Connector BNC
ORP measurement range (-999) to 999 mV
ORP accuracy ± 2 mV
ORP resolution 1 mV