Portable pH/ORP meter LPRPM-A11

Portable pH/ORP meter LPRPM-A11 with high precision can improve temperature measurement accuracy through manual temperature calibration. It measure pH, mV, ORP, temperature of the sample. Equipped with built-in system menu helps in customize selection of up to 9 functional parameters. The unique calibration due reminder alerts user to calibrate the pH meter regularly. The Multi-mode power solution ensures smooth instrument usage. Its complied in accordance with GLP standards.

pH range (-2.00) to 20.00 pH
pH accuracy ± 0.002 pH
pH resolution 0.1, 0.01, 0.001 pH
Calibration points 1 - 5 points
Calibration solutions USA (pH 4.01 / 7.00 / 10.01 / 12.45), NIST(pH 1.68 / 4.01 / 6.86 / 9.18 / 12.45), DIN (pH 1.09 / 4.65 / 6.79 / 9.23 / 12.75) or user defined
Temperature compensation 0 to 100 °C, 32 to 212 °F, Manual or Automatic
mV range (-1999) to 1999 mV
mV accuracy ± 0.2 mV
mV resolution 0.1, 1 mV
Temperature measuring range 0 to 100 °C, 32 to 212 °F
Temperature accuracy ± 0.5 °C, ± 0.9 °F
Temperature resolution 0.1 °C
Hold function Manual
Storage/memory Stores up to 500 data sets
Communication output USB interface
Connector BNC
Dimension (L × W × H) 170 × 85 × 30 mm
Weight 300 g
Battery life About 150 hours
Power 4.5 V “AA batteries or DC 5 V power adapter
  • Measurement pH range: (-2.00) to 20.00 pH
  • pH accuracy: ± 0.002 pH up to three decimal points
  • Auto calibration recognition using 1 to 5 point calibration for pH mode
  • 1 point offset calibration for ORP mode allows to adjust the display value to a known standard
  • The mV measurements (relative & absolute) for accurate ORP readings
  • Automatic end point locking system for stable measurement (browsing & recording)
  • Automatic electrode slope display helps user decide whether to replace the sensor
  • Extended memory can store up to 500 sets of measurement data
  • Built-in clock automatically notes the date, time
  • USB communications interface sends data to PC
  • One touch reset automatically recovers the meter to factory default settings
Temperature probe
pH buffer solution USA(pH 4.01 / 7.00 / 10.01), NIST (pH 4.01 / 6.86 / 9.18)
Suitable pH electrodes

The portable pH/ORP meter has applications in waste water treatment & water management, aquaculture, food & beverage processing, environmental monitoring & research and educational purpose.

Related Products of pH Meters (Portable)

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

pH range (-2.00) to 16.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 2 points

Salinity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Salinity measurement range 0.00 to 10.00 ppt
Salinity accuracy ± 1 % F.S
Conductivity range 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
Calibration solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
Salinity measurement range 0.00 to 80.00 ppt
Salinity accuracy ± 1 % F.S
Conductivity range 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm
Calibration solutions 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
TDS measurement
TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy ± 1 % F.S.
TDS factor 0.1 - 1.0 (default 0.5)
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range 0 to 19999 ppm, mg/L, mol/L
Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
Ion calibration points 2 - 5 points
Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range
Ion accuracy
Ion calibration points
Ion calibration solutions
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Conductivity measurement range 1.0 to 199.9 µS/cm
Type of conductivity Low range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 10 to 1999 µS/cm
Type of conductivity Mid-range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 0.1 to 19.99 mS/cm
Type of conductivity High range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point

pH Meters (Portable)

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

pH range (-2.00) to 20.00 pH
pH accuracy ± 0.002 pH
pH resolution 0.1, 0.01, 0.001 pH
Calibration points 1 - 5 points
pH range (-2.00) to 16.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 2 points

pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

pH measurement range 0.0 - 14.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points