Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.
TDS range | 0.5 - 100.0 ppm |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.4 to 1.0 (default 0.5) |
Calibration points | 1 point |
TDS range | 5 - 1000 ppm |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.4 to 1.0 (default 0.5) |
Calibration points | 1 point |
TDS range | 0.05 - 10.00 ppt |
TDS accuracy | ± 1 % F.S. |
TDS factor | 0.4 to 1.0 (default 0.5) |
Calibration points | 1 point |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Resolution | 0.1 mg / L |
Calibration points | 1 - 2 points |
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.2 mg / L |
Resolution | 0.01 mg / L |
Calibration points | 1 - 2 points |
Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.
pH measurement range | 0.0 - 14.00 pH |
Shape of electrode | Flat pH electrode |
pH measurement accuracy | ± 0.1 pH |
Calibration point | 2 points |
pH measurement range | 0.0 - 14.00 pH |
Shape of electrode | Round glass pH electrode |
pH measurement accuracy | ± 0.1 pH |
Calibration point | 2 points |
pH measurement range | 0.0 - 14.00 pH |
Shape of electrode | Long distance planar pH electrode |
pH measurement accuracy | ± 0.1 pH |
Calibration point | 2 points |
Measuring range (NTU) | 0 to 100, 0 to 200 |
Minimum readout value (NTU) | 0.01, 0.1 |
Calibration point | 4 |
Sample volume | 5 to 10 ml |
Light source | LED/860 nm (Wavelength) |
Readings display | LCD |
Unit switches | NTU, FTU, EBC, ASBC |
Measurement range | 0.00-20.0; 20.01-200; 200.01-1000 NTU |
Measuring range (NTU) | 0 to 200 |
Minimum readout value (NTU) | 0.1 |
Calibration point | Nil |
Sample volume | 5 to 10 ml |
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
||||||||||||||||||
TDS Mode |
|
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
||||||||||||||||||
TDS Mode |
|
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
||||||||||||||||||
Dissolved Oxygen Mode |
|