pH Mode |
pH range |
-2.00 to 20.00 pH |
pH Accuracy |
± 0.002 pH |
pH Resolution |
0.1/0.01/0.001 pH, selectable |
pH Calibration Points |
1 to 5 Points |
pH Buffer Solutions |
USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
|
ORP Mode |
|
mV Mode |
mV Range |
-1999.9 to 1999.9 mV |
mV Accuracy |
± 0.2 mV |
mV Resolution |
0.1/1 mV, selectable |
mV Calibration Points |
1 Point |
|
Ion Mode |
|
Water Hardness Mode |
|
Temperature Mode |
|
Conductivity Mode |
Conductivity Range |
0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm |
Conductivity Accuracy |
± 0.5% F.S. |
Conductivity Resolution |
0.01/0.1/1 |
Conductivity Calibration Points |
1 to 5 Points |
Conductivity Solutions |
10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm |
Conductivity Temperature coefficient |
0.0 to 10.0 %/°C |
Compensation mode |
Linear or Pure Water |
Cell Constant |
K=0.1, 1, 10 or Custom |
Reference temperature |
20 or 25°C |
|
TDS Mode |
|
Salinity Mode |
|
Resistivity Mode |
|
Dissolved Oxygen Mode |
Dissolved Oxygen Range |
0.00 to 20.00 mg/ L |
Dissolved Oxygen Accuracy |
± 0.2 mg/ L |
Dissolved Oxygen Resolution |
0.1/ 0.01 mg/ L, selectable |
Dissolved Oxygen Calibration Points |
1 or 2 Points |
% Saturation Range |
0.0 to 200.0 % with ± 2 % accuracy |
Pressure correction |
60 to 112.5 kPa, 450 to 850 mmHg |
Salinity correction |
0 to 50 g/ L |
|
Temperature Range |
0 to 105°C, 32 to 221°F |
Temperature Accuracy |
± 0.5°C |
Temperature Resolution |
0.1°C |
Temperature Calibrations Points |
1 Point |
Temperature Compensation Mode |
Manual or Automatic |
Data Hold Function |
Manual or Automatic Endpoint Detection |
Stability Criteria |
Low or High |
Calibration Due Alarm |
1 to 31 Days |
Reset Function |
Yes |
Memory |
Stores Up to 500 data sets |
Output |
USB interface |
Connector |
BNC, 6-pin mini plug |
Display |
LCD |
Power supply |
DC5 V, AC 220 V, 50 Hz |
Dimension (L × W × H) |
210 × 188 × 60 mm |
Weight |
1.5 kg |
- Common Features
- Stability indicator displays the status of current measurement
- Auto hold function freezes stable, final readings for better viewing and recording
- Manual temperature calibration to rectify the deviations in temperature
- Automatic temperature compensation for accurate measured value over the entire range
- Selectable temperature units (°C or °F) for different application requirements
- Expanded memory stores and recalls up to 500 readings
- Help message as an operational guide, helps users for quick access to the parameters
- Reset function automatically resumes all the setting back to factory default options
- Store data is transferrable into computer via USB communication interface
- pH mode
- 1-5 points push button calibration to automatically identify pH buffer
- Convenient to select pH buffer standard (USA/NIST/DIN) or custom
- Automatic electrode slope display helps operator whether to replace the sensor
- Conductivity mode
- 1-5 point for calibration with automatically identification of calibration solutions
- Can select cell constant (0.1/1/10) and normalization temperature (20°C or 25°C)
- TDS conversion factor, seawater, practical salinity measurements mode to meet different water quality measurement requirements
- Linear or pure water compensation improves the measurement accuracy
- Dissolved oxygen mode
- 1-2 points calibration using the air-sealed water & zero oxygen solution
- Manual salinity & barometric pressure compensation for accurate readings
Accessories No. |
Name |
1 |
Temperature probe |
2 |
Calibration Solutions for pH and DO electrolyte |
3 |
pH electrodes suitable for non-aqueous, high alkalinity, low conductivity, tis buffers, biofuels and others |
4 |
Dissolved Oxygen Polarographic Probe |
5 |
DO Membrane Cap |
6 |
DC5V power adapter |
Used for quality checking of water on different parameters across research, QC labs, water management plants and others production units.