Online Dissolved Oxygen Controller LODC-A10

Online Dissolved Oxygen Controller LODC-A10 features 1 to 2 points dissolved oxygen calibration system, and 4 to 20 mA output signal transmitter. The large and clear back light LCD displays Calibration and setup values, temperature values, ATC (automatic temperature compensation) values, high and low limit of measurement. It measures the amount of dissolved oxygen in mg/l, ppm units or in % of saturation. The accuracy of measurement is improved by manual salinity and barometric pressure compensation mode.

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen Calibration points 1 - 2 points
Dissolved oxygen accuracy ± 0.5 mg / L
Dissolved oxygen resolution 0.1 mg / L
% of saturation of oxygen range 0.0 to 200.0 %
% of saturation of oxygen accuracy ± 10 % F.S. ± 2.0%
% of saturation of oxygen resolution 0.001
Calibration solutions Saturated anhydrous sodium sulfite solution and air saturated water
Temperature compensation range 0 to 40 °C, 32 °F to 104 °F
Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 - 35 g / L
Signal output 4 to 20 mA
Load Maximum 500 Ω
Low and high alarm limits 1.00 to 18.00 mg/L (selectable)
Connection Interface RS485
Connection terminal Detectable screw terminals
Display LCD screen
Ambient Temperature <60°C
Relative Humidity <80%
Power supply DC 24 V
Dimension (L x W x H) 96 × 96 × 75 mm
Weight 350 g
  • Equipped with a polarographic electrode
  • Use of Zero oxygen solution, air saturated water for calibration
  • 1 to 2 dissolved oxygen calibration points
  • Controller with 4 multifunctional keys with names and symbols
  • ATC mode for accurate readings over entire range
  • Low and high alarm limits set automatically activate an external device
  • System menu allows setting up to 10 parameters
  • Reset features to resumes all setting back to default

Used in water treatment applications across waste water plants, filtration systems, RO treatment water plants, Agriculture, and Aquaculture industry.

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Conductivity measurement range 0.1 to 19.99 mS/cm
Type of conductivity High range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 10 to 1999 µS/cm
Type of conductivity Mid-range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 1.0 to 199.9 µS/cm
Type of conductivity Low range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Ion measurement range Na range: 1 × 10<sup>5</sup> - 1 M, 0.1 - 23000 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Ion measurement range Cl range: 5 × 10<sup>6</sup> - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Ion measurement range F range: 1 × 10<sup>6</sup>M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Residual chlorine/total chlorine
Range 0.00 to 5.00 mg/L
Accuracy 0.001 mg/L 0.001 ABS
Repeatability Lower detection limit ≤0.02 mg/L
Chlorine dioxide
Range 0.00 to 10.00 mg/L
Resolution 0.001 mg/L 0.001 ABS
Accuracy ≤2 mg/L: ±0.10 mg/L ˃2 mg/L: ±5 %
Lower detection limit ≤0.04 mg/L
Light source LED
Wavelength of light 515 nm
Measuring range Water activity 0 to 0.980 aw (no condensing )
Temperature range 0 to 50°C
Measurement accuracy ± 0.015 aw
Temperature accuracy ± 0.5°C
Range 0 to 1.0 aw
Resolution 0 to 1.0 aw
Accuracy ± 0.02 aw
Sensor Nonconductive humidity sensor
Determination range
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error Less or less than 10 %
Sample container/ bottle quantity 1 to 6
Sample container/ bottle Capacity 1000 ml