Pocket pH tester LPPT-A11 comes with 0.0 to 14.00 pH range. Its has flat shape pH electrode. This pH tester has 2 points push button calibration system to automatically identify pH buffer. It is suitable for measuring pH of liquids and semi-solid substance. Pocket pH meter is user friendly in nature & its waterproof performance protects the integrity of the instrument in harsh conditions.

pH measurement range 0.0 - 14.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
Calibration solution USA (pH 4.0/7.00/10.01), NIST (pH 4.01/6.86/9.18)
Operating temperature
Temperature accuracy
Temperature compensation range
Data hold function Manual or Automatic
Connector 6 pin
Shutdown mode Manual or automatic ( 8 minutes without key operations)
Dimension (length × diameter) 185 × 40 mm
Weight 100 g
Power type 3 × 1.5 V G13A button battery 3
Battery life About 150 hours
  • pH measurement range: 0.0 - 14.00 pH
    Flat pH electrode
  • LCD screen display to show the readings
  • 2 points push button calibration to automatically identify pH buffer
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Automatic power off helps to reduce battery power consumption
  • Replaceable electrodes, cost effective maintenance
pH standard buffer solutions USA (pH 4.0/7.00/10.01)
Flat shape pH electrode

Pocket pH tester is suitable for measuring pH of water, waste water, potable water and other liquids and semi-solid substance like gel, agar in enviornmetal monitoring, agriculture, food & beverage industry.

Related Products of pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Different electrodes can be connceted via BNC Connector
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range pH range: (-1.00) to 15.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.01 pH
Calibration point 1 - 3 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Water hardness range 0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L

Salinity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Salinity measurement range 0.00 to 80.00 ppt
Salinity accuracy ± 1 % F.S
Conductivity range 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm
Calibration solutions 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
Salinity measurement range 0.00 to 10.00 ppt
Salinity accuracy ± 1 % F.S
Conductivity range 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
Calibration solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Light source LED/860 nm (Wavelength)
Readings display LCD
Unit switches NTU, FTU, EBC, ASBC
Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU
Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen Calibration points 1 - 2 points
Dissolved oxygen accuracy ± 0.5 mg / L
Dissolved oxygen resolution 0.1 mg / L

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Ion measurement range Cl range: 5 × 10<sup>6</sup> - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Ion measurement range F range: 1 × 10<sup>6</sup>M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Ion measurement range Na range: 1 × 10<sup>5</sup> - 1 M, 0.1 - 23000 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points