Benchtop Conductivity Meter LBCM-A13

Benchtop Conductivity Meter LBCM-A13 with 7 inch display conducts up to 5 point calibration, automatically recognizes calibration standards. Comes with 03 reading mode: fast, medium, strict, custom to balance the work operations. Complied with GLP specifications, meter allows user to carry data statistics, measure results, carry out and review, analyze, and compare statistics.

Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L
Salinity measurement range 0.00 to 8.00 %
Temperature measurement range -5.0 to 135.0 °C
Conductivity accuracy ± 0.5 % FS
Resistivity accuracy ± 0.5 % FS
TDS accuracy ± 0.5 % FS
Salinity accuracy ± 0.1 %
Temperature accuracy ± 0.1  °C
Automatic temperature compensation Yes
Automatic calibration Yes
Automatic range switching Yes
Calibration function Yes
Reading mode
Timed reading Yes
Balanced reading Yes
Continuous reading Yes
Data interface RS232, USB
Data storage 1000 sets
Complied with GLP specifications Yes
Power supply (Input: AC 100 to 240 V, 1.35 A) (Output: DC 24 V, 3A)
Dimension 280 × 280 × 130 mm
Weight 2.5 kg
  • 7 inch color touch screen
  • Automatic temperature compensation and calibration
  • Electrode correction function
  • 5 point conductivity calibrations
  • Intelligent operating system
  • 100 sets of measurement data
  • Different conductivity compensation methods (includes pure water)
  • Different salinity compensation methods (includes saline , brine water)
  • Supports USB, RS232 connection with PC, serial printer
  • Supports firmware upgrade, support U disk hot swap
Accessories No. Name
1 Conductivity Probe (K=0.01)
2 Conductivity Probe (K=0.1)
3 Conductivity Probe (K=1)
4 Conductivity Probe (K=10)

Used to test Conductivity, TDS, Salinity, resistivity values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose.

Related Products of Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Conductivity Mode
Conductivity measurement range 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity accuracy ±1% F.S.
Conductivity resolution 0.001, 0.01, 0.1, 1
Conductivity calibration points 1 to 3 points
Conductivity calibration solutions 10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
TDS Mode
TDS measurement Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.01 to 1.00 (default 0.5)
TDS Calibration points 3 points
Temperature Mode
Temperature range 0 to 105°C, 32 to 221°F
Temperature accuracy ±1°C
Temperature resolution 0.1°C, 0.1°F
Temperature calibration points 1 point
Temperature Compensation Range and Mode Manual or Automatic, 0 to 100°C , 32 to 212°F
Temperature coefficient 0.0 to 10.0 % per °C
Cell constant K=0.1, 1, 10
Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1
Conductivity calibration solutions 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

pH measurement range 0.00 to 14.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 2 points
pH measurement range -1.00 to 15.00 pH
pH accuracy ± 0.01 pH
pH resolution 0.01 pH
Calibration points 1-3 points
Temperature compensation 0 to 100°C, 32°F to 212°F Manual or Automatic
Hold function Manual or automatic endpoint detection
Stability criteria Standard or High-accuracy
Interval readings 10, 30, 60 seconds, 10, 30 minutes or Off

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Water hardness range 0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
pH measurement range 01.00 to 15.00 pH
pH calibration points 1 to 3 points
pH Buffer Solutions USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
pH accuracy ± 0.01 pH

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Conductivity measurement range 1.0 to 199.9 µS/cm
Type of conductivity Low range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 10 to 1999 µS/cm
Type of conductivity Mid-range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 0.1 to 19.99 mS/cm
Type of conductivity High range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
Dissolved Oxygen Mode
Dissolved Oxygen Range 0.00 to 20.00 mg/ L
Dissolved Oxygen Accuracy ± 0.2 mg/ L
Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
Dissolved Oxygen Calibration Points 1 or 2 Points
% Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 to 50 g/ L