Portable turbidity meter LTM-A16

Portable turbidity meter LTM-A16 is a device perceptively aimed with an LCD screen and an automatic power off function comprising of four AA batteries for ultimate usage. The instrument measures a range of 0.00-20.0; 20.01-200; 200.01-1000 NTU. This handy device also features an automatic range switchover that support zero-point and four-point calibration, coherent with ISO7027.The appearance being novel makes it expedient for users in field testing.

Light source LED/860 nm (Wavelength)
Readings display LCD
Unit switches NTU, FTU, EBC, ASBC
Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU
Minimum reading 0.001
Calibration modes 6
Allowable error of indication ≤±6%
Zero Drift ≤±0.5%FS
Stability of indication ≤±0.5% FS
Repeatability ≤0.5%
Sample bottle Φ 25 mm×65 mm
Sample volume 20-25 ml
Interface USB
Data storage 2000 sets
Net Weight 650 gm
  • Implementing big-screen highly transparent LCD display, with comfortable readingbr
  • Entails a sample bottle measuring Φ 25 mm×65 mm
  • Offers a sample volume of 20-25 ml
  • Unique locative backlight set for transpiration
  • Subsidiary zero-point and four-point calibration for precisionism
  • Intended ISO7027 standard for quality presentation
  • Four AA batteries, external power supply, automatic power off function long lasting and effective use
  • Novel in appearance that makes convenient for users in field testing
  • Configured with automatic range switchover for prolong usage

Device is applicable for testing the turbidity of cloudiness in fluids caused by suspended solid particles in bacteriological and research laboratories, haziness in water, food beverages and other aqueous solutions.

Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
Minimum readout value (NTU) 0.01, 0.1
Calibration point 5
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01
Calibration point 2
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100, 100 to 800
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100
Minimum readout value (NTU) 0.001
Calibration point 2
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) 0.01
Calibration point 3
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100, 100 to 1000
Minimum readout value (NTU) 0.01, 0.1
Calibration point 7
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) 0.001
Calibration point 4
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 100 to 500
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 3
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) 0.001
Calibration point 5
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100
Minimum readout value (NTU) 0.01, 0.1
Calibration point 1
Sample volume 5 to 10 ml

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Conductivity measurement range 0.1 to 19.99 mS/cm
Type of conductivity High range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 10 to 1999 µS/cm
Type of conductivity Mid-range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 1.0 to 199.9 µS/cm
Type of conductivity Low range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Light source LED/860 nm (Wavelength)
Readings display LCD
Unit switches NTU, FTU, EBC, ASBC
Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU
Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml

pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

pH measurement range 0.0 - 14.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points
Dissolved oxygen range 0.0 - 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
Calibration points 1 - 2 points
Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
Salinity
Salinity range 0.00 to 80.00 ppt, 0.00 to 42.00 psu
Salinity accuracy ±1% F.S
Salinity measurement modes Practical Salinity (psu) or Natural Seawater (ppt)
Salinity resolution 0.01, 0.1, 1
Temperature
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 3 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
Temperature
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient Linear
Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
TDS
TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS accuracy ±1 % F.S
TDS factor 0.01 to 1.00 (Default 0.5)
TDS resolution 0.01, 0.1, 1
Temperature
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic