Portable Conductivity Meter LPCM-A12

Portable Conductivity Meter LPCM-A12 is adapted with different modes for measuring quality of water on parameters such as conductivity, salinity and temperature. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing and for research purpose. It is reliable and user friendly.

Conductivity
  • Conductivity measurement range: 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
  • Conductivity accuracy: ±0.5% F.S
  • Conductivity calibration points: 1 to 5 points
  • Conductivity calibration solutions: 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
  • Conductivity resolution: 0.001, 0.01, 0.1, 1
Salinity
  • Salinity range: 0.00 to 80.00 ppt, 0.00 to 42.00 psu
  • Salinity accuracy: ±1% F.S
  • Salinity measurement modes: Practical Salinity (psu) or Natural Seawater (ppt)
  • Salinity resolution: 0.01, 0.1, 1
Temperature
  • Temperature measuring range: 0 105 °C, 32 to 221 °F
  • Temperature measuring accuracy: ± °0.5 C, ± 0.9 °F
  • Temperature calibration points: 1 point
  • Temperature resolution: 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient Linear and Pure water compensation
Reference temperature 20 °C or 25 °C
Stability conditions Low or high
Cell constant K= 0.1, 1, 10 or custom
Calibration due 1 to 31 days or off
Memory 500 data sets
Data hold Manual or auto-end point
Connector 6 pin mini plug
Power Control Manual or Automatic (10, 20 or 30 minutes after last key pressed)
Power 3 × 1.5 V AA batteries or DC 5 V power adapter
Dimension (L × W × H) 170 × 85 × 30 mm
Weight 300 g
  • Common features
  • Calibration due reminder informs operator to calibrate the meter regularly
  • Stability indicator displays the status of current measurement
  • Auto hold function freezes stable, final readings for better viewing and recording
  • 1 to 5 points push button calibration to automatically identify calibration solutions
  • Selectable temperature units (°C or °F) for different application requirements
  • Expanded memory stores and recalls up to 500 readings
  • Calibration report provides details of calibration standard and cell constant
  • Help message as an operational guide, helps users for quick access to the parameters
  • Reset function automatically resumes all settings back to factory default options
  • Store data is transferrable into computer via USB communication interface
    Conductivity /Salinity/ Temperature
  • Conductivity: 1 to 5 point calibration with automatically identification of calibration solutions
  • Temperature: Can select cell constant (0.1/1/10) and normalization temperature 20°C or 25°C
  • TDS and Salinity: Seawater, practical salinity measurements mode to meet different water quality measurement requirements
  • linear and pure water compensation improves the measurement accuracy
Number of accessories Accessories name
1 Conductivity electrode for general application
2 Conductivity electrode (K= 0.1): Suitable for measuring the low conductivity liquids ( <10 µS/cm ) for pure water
3 Conductivity electrode (K= 10): Suitable for measuring the high conductivity liquids ( >20 mS/cm ) for sea water

Used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.

Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
TDS
TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS accuracy ±1 % F.S
TDS factor 0.01 to 1.00 (Default 0.5)
TDS resolution 0.01, 0.1, 1
Salinity
Salinity range 0.00 to 80.00 ppt, 0.00 to 42.00 psu
Salinity accuracy ±1% F.S
Salinity measurement modes Practical Salinity (psu) or Natural Seawater (ppt)
Salinity resolution 0.01, 0.1, 1
Resistivity
Resistivity range 0.00 to 20 MΩ
Resistivity accuracy ±1% F.S
Resistivity resolution 0.01, 0.1, 1
Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 3 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
Temperature
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient Linear
Conductivity
Conductivity measurement range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm
Conductivity accuracy ±0.5% F.S
Conductivity calibration points 1 to 5 points
Conductivity calibration solutions 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom
Conductivity resolution 0.001, 0.01, 0.1, 1
TDS
TDS range 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS accuracy ±1 % F.S
TDS factor 0.01 to 1.00 (Default 0.5)
TDS resolution 0.01, 0.1, 1
Temperature
Temperature measuring range 0 105 °C, 32 to 221 °F
Temperature measuring accuracy ± °0.5 C, ± 0.9 °F
Temperature calibration points 1 point
Temperature resolution 0.1 °C, 0.1 °F
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Determination range
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error Less or less than 10 %
Sample container/ bottle quantity 1 to 6
Sample container/ bottle Capacity 1000 ml

pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

pH measurement range 0.0 - 14.00 pH
Shape of electrode Round glass pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Long distance planar pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points
pH measurement range 0.0 - 14.00 pH
Shape of electrode Flat pH electrode
pH measurement accuracy ± 0.1 pH
Calibration point 2 points

Salinity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Salinity measurement range 0.00 to 10.00 ppt
Salinity accuracy ± 1 % F.S
Conductivity range 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
Calibration solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
Salinity measurement range 0.00 to 80.00 ppt
Salinity accuracy ± 1 % F.S
Conductivity range 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm
Calibration solutions 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Light source LED/860 nm (Wavelength)
Readings display LCD
Unit switches NTU, FTU, EBC, ASBC
Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
Calibration points 1 - 2 points