Conductivity measurement range | 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm |
Conductivity calibration points | 1 to 3 points |
Conductivity accuracy | ±1 % F.S. |
Conductivity resolution | 0.001/ 0.01/ 0.1/ 1 |
Conductivity |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic | ||||||||||
Temperature coefficient | Linear |
Conductivity |
|
||||||||||
Salinity |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
Conductivity |
|
||||||||||
TDS |
|
||||||||||
Temperature |
|
||||||||||
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
Light source | LED/860 nm (Wavelength) |
Readings display | LCD |
Unit switches | NTU, FTU, EBC, ASBC |
Measurement range | 0.00-20.0; 20.01-200; 200.01-1000 NTU |
Measuring range (NTU) | 0 to 100, 0 to 200 |
Minimum readout value (NTU) | 0.01, 0.1 |
Calibration point | 4 |
Sample volume | 5 to 10 ml |
Measuring range (NTU) | 0 to 200 |
Minimum readout value (NTU) | 0.1 |
Calibration point | Nil |
Sample volume | 5 to 10 ml |
Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.
Salinity measurement range | 0.00 to 10.00 ppt |
Salinity accuracy | ± 1 % F.S |
Conductivity range | 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm |
Calibration solutions | 84 µS/cm, 1413 µS/cm, 12.88 mS/cm |
Salinity measurement range | 0.00 to 80.00 ppt |
Salinity accuracy | ± 1 % F.S |
Conductivity range | 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm |
Calibration solutions | 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm |
Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.
pH mode |
|
||||||||||||||||
ORP measurement |
|
||||||||||||||||
Conductivity measurement |
|
||||||||||||||||
TDS measurement |
|
pH mode |
|
||||||||||||||||
ORP measurement |
|
||||||||||||||||
Ion measurement |
|
||||||||||||||||
Conductivity measurement |
|
pH mode |
|
||||||||||||||||
ORP measurement |
|
||||||||||||||||
Ion measurement |
|
||||||||||||||||
Conductivity measurement |
|