Pocket Dissolved oxygen tester LPKDO-A10

Pocket Dissolved oxygen tester LPKDO-A10 is equipped with polarographic sensor to measure dissolved oxygen content. The system menu of dissolved oxygen meter can set 6 parameters which includes the number of calibration points, temperature units etc. It can measure the dissolved oxygen content present in water, waste water, other liquids & solutions.

Dissolved oxygen range 0.0 to 20.0 mg/L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg/L
% of saturation of oxygen 0.0 to 200.0%
Sensor type Polarographic dissolved oxygen probe
% Saturation of oxygen accuracy ± 10 % F.S.
Temperature compensation range 0 °C to 40 °C, 32 °F to 104 °F
Barometric pressure correction 60.0 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 - 35 g/L
Data hold function Manual or automatic
Power off Manual or automatic (8 minute after last key is pressed)
Reset function Yes
Connector 6 pin mini plug
Battery life Approximately 150 hours
Dimension (L × Dia.) 175 × 40 mm
Weight 100 g
  • Equipped with polarographic sensor
  • 1 - 2 points calibration using air saturated water & zero oxygen solution
  • Manual salinity & barometric pressure compensation for better measurement of dissolved oxygen
  • System menu allows setting the 6 parameters
  • Automatic temperature compensation for accurate measured value over the entire range
  • Auto hold function freezes stable, final readings for better viewing and recording
  • Automatic power off helps to reduce battery power consumption
  • Waterproof features guarantees protection against harsh conditions
  • Battery indicator to show the remaining battery capacity
  • Reset function automatically resumes all the settings to default mode
Polarographic sensor
30 ml electrolyte solution per bottle
Membrane cap

Pocket Dissolved oxygen tester has applications in water & waste water management industry, aquarium, surface ground water, etc. to detect content of dissolved oxygen.

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Conductivity measurement range 10 to 1999 µS/cm
Type of conductivity Mid-range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 1.0 to 199.9 µS/cm
Type of conductivity Low range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point
Conductivity measurement range 0.1 to 19.99 mS/cm
Type of conductivity High range conductivity
Conductivity accuracy ± 1 % F.S.
Conductivity calibration points 1 point

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Water hardness range 0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L

Portable Multi Parameter Water Quality Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range
Ion accuracy
Ion calibration points
Ion calibration solutions
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Ion measurement
Ion measurement range 0 to 19999 ppm, mg/L, mol/L
Ion accuracy ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
Ion calibration points 2 - 5 points
Ion calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
pH mode
pH measurement range (-2.000) to 20.000 pH
pH accuracy ± 0.002 pH
pH calibration points 1 - 5 points
pH calibration solutions USA, NIST, DIN or user defined
ORP measurement
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration solutions mV & relative mV
Conductivity measurement
Conductivity measurement range 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy ± 0.5 % F.S.
Conductivity calibration points 1 - 5 points
Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient 0.0 to 10.0 % / °C
Compensation modes Linear or pre water
Cell constant K = 0.1, 1, 10 or user-defined
Normalization temperature 20 °C or 25 °C
TDS measurement
TDS range 0-100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy ± 1 % F.S.
TDS factor 0.1 - 1.0 (default 0.5)
Measurement range 20000 mg/L <br/> 0.01 mg/L ~ 45000 mg/L <br/> 0.01 mg/L ~ 120000 mg/L
Measurement accuracy ± 2 % F.S. of its range ( Depending on the homogeneity of sludge)
Pressure range ≤ 0.4 Mpa
Flow rate ≤ 2.5 m/s, 8.2 ft./s

TDS Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

TDS range 0.5 - 100.0 ppm
TDS accuracy ± 1 % F.S.
TDS factor 0.4 to 1.0 (default 0.5)
Calibration points 1 point
TDS range 5 - 1000 ppm
TDS accuracy ± 1 % F.S.
TDS factor 0.4 to 1.0 (default 0.5)
Calibration points 1 point
TDS range 0.05 - 10.00 ppt
TDS accuracy ± 1 % F.S.
TDS factor 0.4 to 1.0 (default 0.5)
Calibration points 1 point