Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
| Conductivity measurement range | 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
| Conductivity accuracy | ± 1 % F.S. |
| Conductivity resolution | 0.01, 0.1, 1 |
| Conductivity calibration solutions | 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm |
| Conductivity Mode |
|
||||||||||||
| TDS Mode |
|
||||||||||||
| Temperature Mode |
|
||||||||||||
| Cell constant | K=0.1, 1, 10 |
| Conductivity measurement range | 0.000 μS/cm to 3000mS/cm |
| Resistivity measurement range | 5.00 Ω·cm to 100.0 MΩ·cm |
| TDS measurement range | 0.000 mg/L to 1000g/L |
| Salinity measurement range | 0.00 to 8.00 % |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
| Ion measurement range | Na range: 1 × 10<sup>5</sup> - 1 M, 0.1 - 23000 ppm |
| Ion measurement accuracy | ± 0.5 % F.S. |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration points | 2 to 5 points |
| Ion measurement range | F range: 1 × 10<sup>6</sup>M – saturation, 0.02 ppm to saturation |
| Ion measurement accuracy | ± 0.5 % F.S. |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration points | 2 to 5 points |
| Ion measurement range | Cl range: 5 × 10<sup>6</sup> - 1 M, 1.8 - 35500 ppm |
| Ion measurement accuracy | ± 0.5 % F.S. |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration points | 2 to 5 points |
| Conductivity |
|
||||||||||
| TDS |
|
||||||||||
| Temperature |
|
||||||||||
| Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
| Conductivity |
|
||||||||||
| Salinity |
|
||||||||||
| Temperature |
|
||||||||||
| Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
| Conductivity |
|
||||||||||
| Temperature |
|
||||||||||
| Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic | ||||||||||
| Temperature coefficient | Linear |
| pH measurement range | 01.00 to 15.00 pH |
| pH calibration points | 1 to 3 points |
| pH Buffer Solutions | USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18) |
| pH accuracy | ± 0.01 pH |
| Measurement range | 20000 mg/L <br/> 0.01 mg/L ~ 45000 mg/L <br/> 0.01 mg/L ~ 120000 mg/L |
| Measurement accuracy | ± 2 % F.S. of its range ( Depending on the homogeneity of sludge) |
| Pressure range | ≤ 0.4 Mpa |
| Flow rate | ≤ 2.5 m/s, 8.2 ft./s |