Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Water hardness range | 0.05 mmol / L -0.2 mol / L <br/> (CaCO<sub>3</sub>) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L<br/> (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f |
Accuracy | ± 1 % F.S. |
Calibration points | 2 to 5 points |
Calibration solution | 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L |
Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Resolution | 0.1 mg / L |
Calibration points | 1 - 2 points |
Dissolved oxygen range | 0.0 - 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.2 mg / L |
Resolution | 0.01 mg / L |
Calibration points | 1 - 2 points |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Temperature compensation | 0 to 100°C, 32°F to 212°F Manual or Automatic |
Hold function | Manual or automatic endpoint detection |
Stability criteria | Standard or High-accuracy |
Interval readings | 10, 30, 60 seconds, 10, 30 minutes or Off |
pH measurement range | 0.00 to 14.00 pH |
pH accuracy | ± 0.01 pH |
pH resolution | 0.01 pH |
Calibration points | 2 points |
pH measurement range | -1.00 to 15.00 pH |
pH accuracy | ± 0.01 pH |
pH resolution | 0.01 pH |
Calibration points | 1-3 points |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Conductivity measurement range | 0.000 μS/cm to 3000mS/cm |
Resistivity measurement range | 5.00 Ω·cm to 100.0 MΩ·cm |
TDS measurement range | 0.000 mg/L to 1000g/L |
Salinity measurement range | 0.00 to 8.00 % |
Conductivity measurement range | 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
Conductivity accuracy | ± 1 % F.S. |
Conductivity resolution | 0.01, 0.1, 1 |
Conductivity calibration solutions | 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm |
Conductivity Mode |
|
||||||||||||
TDS Mode |
|
||||||||||||
Temperature Mode |
|
||||||||||||
Cell constant | K=0.1, 1, 10 |
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen Calibration points | 1 - 2 points |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Dissolved oxygen resolution | 0.1 mg / L |