Portable Turbidity Meter LTM-A10

Portable Turbidity meter LTM-A10 with microprocessor controlled system, utilizes 90° scattered light principle to measure water turbidity in nephelometric turbidity unit i.e. NTU. The formazine standard solution of turbidity mentioned in ISO 7027 is used for turbidity analysis. Portable meter, used in field and lab scale analysis, delivers highly accurate results as per the GLP standards.

Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml
Principle method 90° scattered light
Operating temperature 5 to 40°C
Working temperature 5 to 40°C
Light source Infrared-emitting diode (850 nm λ)
Detector Silicon photodiode
Error value ± 6 % (± 2 % F.S)
Zero drift ± 0.5 % F.S.
Reset functions Yes
Memory Stores up to 20 sets data
Output
Dimension 370 × 260 × 150 mm
Weight 1.5 kg
Power batteries DC 1.5 V, 5 AA alkaline batteries
Power supply AC 220 V, 50 Hz
  • Quick and automatic multi-points calibration
  • LCD display with touch keypad
  • Non- linear data processing and transfer
  • Selectable automatic or manual switch mode
  • High through put stability
  • Auto shut down system
  • Easy to use
  • Standard carrying case for field analysis
Accessory No. Name
1 USB communication interface

Used to test turbidity of water across water testing plants, water recycling units, and food and beverage units as a quality and research parameter.

Measuring range (NTU) 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) 0.01
Calibration point 3
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100, 100 to 500
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
Minimum readout value (NTU) 0.01, 0.1
Calibration point 5
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01
Calibration point 2
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 3
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 100 to 800
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100
Minimum readout value (NTU) 0.001
Calibration point 2
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000
Minimum readout value (NTU) 0.01, 0.1
Calibration point 6
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 100 to 400
Minimum readout value (NTU) 0.01, 0.1
Calibration point 5
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) 0.001
Calibration point 4
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100
Minimum readout value (NTU) 0.01, 0.1
Calibration point 1
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) 0.001
Calibration point 5
Sample volume 18 to 20 ml
Measuring range (NTU) 0 to 100, 100 to 1000
Minimum readout value (NTU) 0.01, 0.1
Calibration point 7
Sample volume 5 to 10 ml

Portable Dissolve Oxygen Meter

Labtron portable meters are used in quality analysis of water and other solutions. With portability, waterproof features, finds applications in indoor as well as outdoor measurement of pH, ORP, dissolved oxygen, water hardness, salinity, TDS etc.

Dissolved oxygen range 0.0 - 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
Calibration points 1 - 2 points
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Calibration points 1 - 2 points
Measuring range (NTU) 0 to 200
Minimum readout value (NTU) 0.1
Calibration point Nil
Sample volume 5 to 10 ml
Measuring range (NTU) 0 to 100, 0 to 200
Minimum readout value (NTU) 0.01, 0.1
Calibration point 4
Sample volume 5 to 10 ml
Light source LED/860 nm (Wavelength)
Readings display LCD
Unit switches NTU, FTU, EBC, ASBC
Measurement range 0.00-20.0; 20.01-200; 200.01-1000 NTU
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
Dissolved Oxygen Mode
Dissolved Oxygen Range 0.00 to 20.00 mg/ L
Dissolved Oxygen Accuracy ± 0.2 mg/ L
Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable
Dissolved Oxygen Calibration Points 1 or 2 Points
% Saturation Range 0.0 to 200.0 % with ± 2 % accuracy
Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg
Salinity correction 0 to 50 g/ L
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
TDS Mode
TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
TDS Accuracy ± 1 % F.S.
TDS Factor 0.1  to 1.0 (default 0.5)
Residual chlorine/total chlorine
Range 0.00 to 5.00 mg/L
Accuracy 0.001 mg/L 0.001 ABS
Repeatability Lower detection limit ≤0.02 mg/L
Chlorine dioxide
Range 0.00 to 10.00 mg/L
Resolution 0.001 mg/L 0.001 ABS
Accuracy ≤2 mg/L: ±0.10 mg/L ˃2 mg/L: ±5 %
Lower detection limit ≤0.04 mg/L
Light source LED
Wavelength of light 515 nm

Dissolved Oxygen Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Dissolved oxygen range 0.0 to 20.0 mg/L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg/L
% of saturation of oxygen 0.0 to 200.0%
Sensor type Polarographic dissolved oxygen probe