Automatic Tag Closed Flash Point Tester LACF-A10

Automatic Tag Closed Flash Point Tester LACF-A10 is a highly automated machine with -50°C lowest flash point and simple operations. Used to determine flash point of liquids with viscosity below 5.5 cSt (mm2/s) at 40°C (104°F) or below 9.5 cSt (mm2/s) at 25°C (77°F) and flash point below 93°C (200°F) . Test method is complied with ASTM D56 international standard.

Experimental temperature range -50 to 70°C
Test sample volume 50 ml
Ambient temperature range 10 to 40°C
Humidity ≤ 85%
Ignition gas source Pipelined gas or LPG
Gas pressure < 10 kPa
Cooling method 2 Danfoss compressor refrigeration
Temperature Sensor Glass PT100 sensor
Display Touch screen LCD display
Printing method Thermal printer
Dimension 700 × 700 × 750 mm
Weight 110 kg
Power supply AC 200 V ± 10 % 50 Hz
Power 1500 W
  • Fast cooling speed
  • Equipped with liquid position overflow port, filling port
  • High depth testing at -50°C (lowest flash point) for test sample
  • Adopted with stainless steel, anti-aging gas circuit
  • 50 ml Test sample volume

Used in analysis of flash point of materials at low temperature value across petroleum, chemical, oil, paint and other industries.

Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Power of motor 2 kW
Ambient temperature ≤ 35 ℃
Relative humidity ≤ 85 %
Heating power of electric furnace 250 W × 2
Total power consumption ≤ 700 W
Beaker quantity 600 ml
Ambient temperature (-10) °C ~ 40 °C
Relative humidity ≤ 85 %
Thermometer Measurement range (-5) °C ~ 300 °C
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Operation temperature of water bath RT ~ 90 °C
Temperature controlling accuracy ± 0.1 °C
Dimensions 550 × 520 × 102 mm
Pressure meter accuracy ± 0.4 % kPa
Test bomb Two samples or a group of parallel samples
Bath temperature 37.8 °C
Temperature controlling accuracy 0.1 °C
Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm