Labtron LAPT-A10 is designed with stepless speed regulation motor to have a smoother operation and automatic alarm system with sound and light to detect end point. It is designed and made as per ASTM D611 “Test Methods for Aniline Point of Petroleum Products”.

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Exterior Dimension 370 × 320 × 630 mm
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling accuracy
Temperature controlling range
Power supply for illumination
Power of motor
  • Electric heater to heat sample
  • Reliable and convenient
  • Controlling temperature can be adjusted manually
  • Highly accurate

It can be widely used in petroleum, chemical industries, research and development laboratories.

Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Power of motor 2 kW
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time