Aniline Point Tester LAPT-A10

Labtron LAPT-A10 is designed with stepless speed regulation motor to have a smoother operation and automatic alarm system with sound and light to detect end point. It is designed and made as per ASTM D611 “Test Methods for Aniline Point of Petroleum Products”.

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Exterior Dimension 370 × 320 × 630 mm
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling accuracy
Temperature controlling range
Power supply for illumination
Power of motor
  • Electric heater to heat sample
  • Reliable and convenient
  • Controlling temperature can be adjusted manually
  • Highly accurate

It can be widely used in petroleum, chemical industries, research and development laboratories.

Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Power of motor 2 kW
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Coking furnace Metal furnace
Heating mode Electric heating
Test unit 5 units
Temperature range Ambient to 550°C
Bath type Four holes with a furnace
Heating type Electric resistance furnace
Temperature controlling range 0 ~ 520 °C
Temperature controlling accuracy ± 5 °C
Porcelain crucible 30 ml
Inner iron crucible 75 ml
Outer iron crucible 190 ml
Burner Mig Burner
Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Total power consumption ≤ 1200 W
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Vessel Volume  4000 ml × 2
Power of Vacuum pump 160 W
Negative power 3.7 kPa(27.75 mmHg)
Power of shaking machine 30 W