Aniline Point Tester LAPT-A10

Labtron LAPT-A10 is designed with stepless speed regulation motor to have a smoother operation and automatic alarm system with sound and light to detect end point. It is designed and made as per ASTM D611 “Test Methods for Aniline Point of Petroleum Products”.

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Exterior Dimension 370 × 320 × 630 mm
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling accuracy
Temperature controlling range
Power supply for illumination
Power of motor
  • Electric heater to heat sample
  • Reliable and convenient
  • Controlling temperature can be adjusted manually
  • Highly accurate

It can be widely used in petroleum, chemical industries, research and development laboratories.

Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Power of motor 2 kW
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
Ambient temperature ≤ 35 ℃
Relative humidity ≤ 85 %
Heating power of electric furnace 250 W × 2
Total power consumption ≤ 700 W
Beaker quantity 600 ml
Ambient temperature (-10) °C ~ 40 °C
Relative humidity ≤ 85 %
Thermometer Measurement range (-5) °C ~ 300 °C
Bath type Oil bath
Bath capacity 5000 ml ± 50 ml
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Evaporation bath type and size Aluminum bath φ260 × 130 mm
Holes for testing 5 pieces
Size of holes for testing cylinder φ51 × 70 mm
Working temperature 160 ℃ ~ 165℃
Evaporation bath type and size Aluminum block bath, φ260 × 130 mm
Holes for testing 3 pieces
Size of holes for testing cylinder φ51 × 70 mm
Flow rate display Flow meter
Measurement range 0 to 600 penetration scale
Timing controller 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Penetrometer
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.1 penetration
Penetration accuracy ± 1 penetration
Weight of standard needle 2.5 ± 0.05 g
Dimensions (W × L × H) 700 × 400 × 750 mm
Weight 30 kg
Circulatory Water Bath
Bath volume 3.5 L
Temperature range 5 °C to 60 °C
Temperature accuracy ± 0.1 °C
Circulatory water quantity 3 L/minute
Pump Lift 2 m
Power consumption 1200 W
Power supply AC 220V ± 10 %, 50 Hz
Dimensions (W × L × H) 600 × 400 × 650 mm
Weight 40 kg