Kinematics Viscometer LKV-A11

Labtron LKV-A11 Kinematic Viscometer is used for precise measurement with capillary viscometers. It is made according to “Test Methods for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity” as per ASTM D445.

Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Sample quantity
Bath temperature
Measurement range
Bath cubage
Temperature controlling range
Temperature controlling accuracy ± 0.1 °C
Illumination
Constant temperature bath 20 L; two layers water bath
Timing range
Barometric
Timing accuracy
Timing device
Temperature sensor Industrial platinum resistance; Pt100
Inner capillary viscometer diameters 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5 and 4.0 mm respectively (inner diameters of 5.0 and 6.0mm are optional)
Mercury thermometer scale division
  • LCD temperature controller
  • High Temperature control accuracy which can reach ± 0.1 ℃
  • Uniform water bath temperature
  • Electric stirring device
  • Convenient to operate and gives fast response

It is used in the fields of petroleum & its products industries, research and development department.

Ambient temperature 15 to 35°C
Relative humidity ≤ 85%
Capillary viscometer 6 capillary Pinkevitch viscometer tubes
Stirring motor 1200 rpm
Ambient temperature 0 ~ 40 ºC
Relative humidity 20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy ± 0.1 °C
Timing range 0.0 s ~ 9999.9 s
Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Capillary viscometer 13 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Potential measuring range (0 to ±1999.5) Mv
Intrinsic error 0.1 % ±0.5 mV
Input impedance Ri ≥1 × 1012 Ω
Burette capacity 10 mL
 Temperature range Room temperature to 1000 ºC
Temperature resolution 0.1 ºC
Temperature fluctuation ±0.1 ºC
Heating rate 1 ~ 80 ºC / min
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C