Benzene Distillation Tester (Low Temperature) LDT-A11

Benzene Distillation Tester (Low Temperature) LDT-A11 is a low temperature distillation tester which determines distillation characteristics of benzene, toluene and xylene. It has desktop structure and the distillation flask of the instrument can withstand temperature of more than 500°C.

Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Total length 8000 mm
Water cooling tube 4500 mm
Heating power system 1000 W
Total power consumption ≤ 1100 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Easy installation
  • Desktop structure
  • Distillation flask endures temperature of more than 500°C
  • Simple design
  • Heating power can be unremittingly adjusted
  • It is also used to determine benzene, toluene, and xylene

It is used for determining the boiling points of gasoline, aviation gasoline, jet fuel vapor, distillate fuel, and diesel oil.

Graduated flasks 10 ml and 100 ml
Scale division of graduated flask 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Distillation flask 125 mL
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Graduated flasks 100 ml
Scale division of graduated flask 1 ml
Outer diameter of distillation flask φ65
Refrigeration tube φ14
Ambient temperature 5 °C to 35 ℃
Relative humidity ≤ 85 %
Cubage of buffer vessel 1000 ml
Max. Residual pressure ≤ 2 mm Hg
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Graduated flasks 100 ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Graduated flasks 100 ml
Distillation flask 125 mL
Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Viscosity measurement range 10 ~ 2000000 MPa•s
Ambient temperature 5 °C ~ 35 °C
Ambient humidity Not more than 80 %
Spindles Four spindles of No.1 ~ 4
Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %