Wax Oil Content Tester LWCT-A22

Labtron LWCT-A22 is manufactured with glass float-type flow meter, designed refrigeration device and digital temperature controller. We meticulously designed it for precision and accuracy.

Light source
Temperature of grinding milk white light bulb
Light hole( Φ14)
Color comparing tube
Dimension
Non-colorful flat bottom glass tube
Observation lens
Total power consumption
Power supply AC 220 V ± 10 %, 50 Hz
Heating power of water bath
Relative humidity
Ambient temperature
Temperature display mode of water bath
Temperature controlling range in water bath RT ~ 90 ℃ ± 5 ℃
Temperature controlling accuracy in water bath:
Temperature controlling range in funnel
Temperature display mode of funnel
Temperature controlling accuracy in funnel
Controlling case (L × W × H)
Water bath (L × W × H)
Cooling bath temperature (-35) ℃ ± 1 ℃
Evaporation temperature 35 ℃ ± 1 ℃
Flow rate 2 ~ 3 L / min
Timing range of timer 0 ~ 60 min
Measurement range
Voltage rising rate
Distance between electrodes
Output power
  • Two samples test simultaneously
  • Digital temperature controller
  • Glass flow meter
  • Desktop structure, novel and convenient
  • Refrigeration device present

It is extensively used in petroleum, chemical and research industry.

Dimension 390 x 260 x 590 mm
Total power consumption ≤ 1200 W
Power supply AC 220 V ± 10 %, 50 Hz
Heating power of water bath 1000 W
Power supply AC 220 V ± 5 % , 50Hz
Measurement range 0 ~ 75 kV
Voltage rising rate 3 kV ± 10 % / s
Distance between electrodes 2.5 mm
Light source 220 V, 100 W
Temperature of grinding milk white light bulb 2750 ± 50 K
Light hole( Φ14) 26 pieces
Color comparing tube Φ32 mm
Ambient temperature 10 °C ~ 40 °C
Relative humidity ≤ 80 %
Measurement Range Ambient Temperature ~ 250 °C
Flash Point Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Coking furnace Metal furnace
Heating mode Electric heating
Test unit 5 units
Temperature range Ambient to 550°C
Bath type Four holes with a furnace
Heating type Electric resistance furnace
Temperature controlling range 0 ~ 520 °C
Temperature controlling accuracy ± 5 °C
Porcelain crucible 30 ml
Inner iron crucible 75 ml
Outer iron crucible 190 ml
Burner Mig Burner
Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz
Ambient temperature ≤ 35 ℃
Relative humidity ≤ 85 %
Heating power of electric furnace 250 W × 2
Total power consumption ≤ 700 W
Beaker quantity 600 ml
Ambient temperature (-10) °C ~ 40 °C
Relative humidity ≤ 85 %
Thermometer Measurement range (-5) °C ~ 300 °C