Wax Oil Content Tester LWCT-A22

Wax Oil Content Tester LWCT-A22

Labtron LWCT-A22 is manufactured with glass float-type flow meter, designed refrigeration device and digital temperature controller. We meticulously designed it for precision and accuracy.

Specifications

Features

Applications

Download Catalog

Power supplyAC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bathRT ~ 90 ℃ ± 5 ℃
Cooling bath temperature(-35) ℃ ± 1 ℃
Evaporation temperature35 ℃ ± 1 ℃
Flow rate2 ~ 3 L / min
Timing range of timer0 ~ 60 min

Related Products of Other Instrument

Mechanical Impurity Tester (Weight Method) LMIT-A21

Mechanical Impurity Tester (Weight Method) LMIT-A21

Color Tester LCT-A20

Color Tester LCT-A20

Light source220 V, 100 W
Temperature of grinding milk white light bulb2750 ± 50 K
Light hole( Φ14)26 pieces
Insulating Oil Breakdown Voltage Tester LIBT-A23

Insulating Oil Breakdown Voltage Tester LIBT-A23

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

Calorimeter typeIsoperibol
Oxygen fillingSemi-automatic
Bomb volume282 ml
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

Calorimeter typeIsoperibol
Temperature range5 to 40°C
Measurement range5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

Calorimeter typeIsoperibol
Oxygen fillingFully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume250 ml
Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

Calorimeter typeIsoperibol
Temperature range5 to 40°C
Measurement range5 to 40 MJ/ kg

Octane Number & Cetane Number Tester

Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

Measurement itemmotor gasoline and diesel
measurement unit of octane is ON40 to 120
Permissible error of octane± 0.5 max
Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

 Measuring Range For Aviation Gasoline86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor VehiclesNational standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For EthanolE93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON

Acid and Alkali Tester

Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask100 ml,50 ml
Conical flask100ml
Separatory funnel250ml
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

Measurement rangeRoom temperature ~ 150°C
Stirring speed0 ~ 1200 r / min
Heating power25 W

Closed Cup Flash Point Tester

PMCC Flash Point Tester LCFP-A10

PMCC Flash Point Tester LCFP-A10

Ambient temperature≤ 35 °C
Relative humidity≤ 85 %
Automatic PMCC Flash Point Tester LCFP-A11

Automatic PMCC Flash Point Tester LCFP-A11

Ambient temperature10 °C ~ 40 °C
Relative humidity≤ 80 %
Automatic PMCC Flash Point Tester LCFP-A13

Automatic PMCC Flash Point Tester LCFP-A13

Ambient temperature10 °C ~ 40 ℃
Relative humidity≤ 80 %
Ignition Modeelectron igniter / gas flame

Demulsibility Characteristics Tester

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A10

Ambient temperatureRoom temperature to 35 °C
Relative humidity≤ 85 %
Timing range1 s to 9 min 59 s
Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

Ambient temperatureRoom temperature to 35 °C
Relative humidity≤ 85 %

Density Tester

Density Tester LDMT-A10

Density Tester LDMT-A10

Cubage of bathФ300 × 380 mm
Temperature controlling range0 °C ~ 100 °C
Temperature controlling accuracy± 0.2 °C

Distillation Tester

Distillation Tester (low temperature Double units) LDT-A16

Distillation Tester (low temperature Double units) LDT-A16

Graduated flasks100 ml
Distillation flask125 ml
Ambient temperature≤ 35 °C
Distillation Tester LDT-A12

Distillation Tester LDT-A12

Graduated flasks100 ml
Scale division of graduated flask1 ml
Outer diameter of distillation flaskφ65
Distillation Tester Front Type LDT-A14

Distillation Tester Front Type LDT-A14

Distillation flask125 mL
Ambient temperatureRoom temperature to 35 °C
Relative humidity≤ 85 %
Distillation Tester Dual Units LDT-A15

Distillation Tester Dual Units LDT-A15

Graduated flasks100 ml
Scale division of graduated flask1ml
Distillation flask125 ml
Distillation Tester LDT-A10

Distillation Tester LDT-A10

Graduated flasks10 ml and 100 ml
Scale division of graduated flask10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature(-10) °C ~ 35 °C
Automatic Distillation Apparatus LADA-A10

Automatic Distillation Apparatus LADA-A10

Heating power2 kW
Cooling power0.5 kW
Steam temperature0 to 400℃
Distillation Tester (low temperature single unit) LDT-A17

Distillation Tester (low temperature single unit) LDT-A17

Graduated flasks100 ml
Distillation flask125 mL
Ambient temperature≤ 30 °C
Vacuum Distillation Tester LDT-A13

Vacuum Distillation Tester LDT-A13

Ambient temperature5 °C to 35 ℃
Relative humidity≤ 85 %
Cubage of buffer vessel1000 ml
Benzene Distillation Tester (Low Temperature) LDT-A11

Benzene Distillation Tester (Low Temperature) LDT-A11

Ambient temperature-10°C to 35°C
Relative humidity≤ 85 %
ThermometerEach one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C

Dropping Point Tester

Dropping Point Tester (Oil Bath) LDPT-A10

Dropping Point Tester (Oil Bath) LDPT-A10

Beaker quantity600 ml
Ambient temperature(-10) °C ~ 40 °C
Relative humidity≤ 85 %
Dropping Point Tester (Air bath) LDPT-A11

Dropping Point Tester (Air bath) LDPT-A11

Ambient temperature≤ 35 ℃
Relative humidity≤ 85 %

Engler Viscometer

Engler Viscometer LEV-A11

Engler Viscometer LEV-A11

Graduated Flask100 ml
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C
Engler Viscometer LEV-B10

Engler Viscometer LEV-B10

Graduated Flask200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C
Engler Viscometer LEV-A10

Engler Viscometer LEV-A10

Graduated Flask200 ± 0.2 ml
Standard Water Value51 ± 1 s
Temperature Range0 ~ 100 °C

Existent Gum Tester

Existent Gum Tester LEGT- B31

Existent Gum Tester LEGT- B31

Existent Gum Tester LEGT- B30

Existent Gum Tester LEGT- B30

Bath typeOil bath
Bath capacity5000 ml ± 50 ml
Ambient temperatureRoom temperature to 35 °C
Existent Gum Tester LEGT- B32

Existent Gum Tester LEGT- B32

Kinematics Viscometer

Kinematics Viscometer LKV-A10

Kinematics Viscometer LKV-A10

Ambient temperature15 to 35°C
Relative humidity≤ 85%
Capillary viscometer6 capillary Pinkevitch viscometer tubes
Kinematics Viscometer LKV-A15

Kinematics Viscometer LKV-A15

Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer11 pieces
Low Temperature Kinematic Viscosity Tester LKV-A14

Low Temperature Kinematic Viscosity Tester LKV-A14

Ambient temperature≤ 30 °C
Relative humidity≤ 85 %
Capillary viscometer13 pieces
Kinematics Viscometer LKV-A16

Kinematics Viscometer LKV-A16

Ambient temperature0 ~ 40 ºC
Relative humidity20 ~ 90 %, RH while 40 ℃
Kinematics Viscometer LKV-A12

Kinematics Viscometer LKV-A12

Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer11 pieces
Kinematics Viscometer LKV-A11

Kinematics Viscometer LKV-A11

Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer11 pieces
Kinematics Viscometer LKV-A13

Kinematics Viscometer LKV-A13

Ambient temperature(-10) °C ~ 35 °C
Relative humidity≤ 85 %
Capillary viscometer7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group

Low Temperature Tester

Automatic Pour Point Tester LLTT-A23

Automatic Pour Point Tester LLTT-A23

Pour and Cloud Point Tester LLTT-A14

Pour and Cloud Point Tester LLTT-A14

Chamber quantity2 chambers
Chamber 01 temperature controlAmbient to -51 ℃
Chamber 02 temperature controlAmbient to -65 ℃
Solidifying Point Tester LLTT-A13

Solidifying Point Tester LLTT-A13

Temperature controlling accuracy± 0.5 ℃
Refrigeration systemNew-type refrigeration compressor
Solidifying Point Constant Temperature Water Bath LLTT-A10

Solidifying Point Constant Temperature Water Bath LLTT-A10

Capacity20 L
Temperature rangeAmbient +5°C to 100°C
Precision± 0.1℃
Freezing Point Tester LLTT-A11

Freezing Point Tester LLTT-A11

Freezing point range-54°C to 2°C
Cold bath measurement temperature range-70° to 20°C
Temperature controlling accuracy±0.5°C
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21

Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21

Refrigeration systemNew-type refrigeration compressor
Multifunctional Low Temperature Tester LLTT-A16

Multifunctional Low Temperature Tester LLTT-A16

Refrigeration systemNew-type refrigeration compressor
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12

Solidifying Point Tester ('-20°C +80°C') LLTT-A22

Solidifying Point Tester ('-20°C +80°C') LLTT-A22

Temperature controlling accuracy± 0.5 °C
Refrigeration systemNew-type refrigeration compressor
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15

Refrigeration systemNew-type refrigeration compressor
Solidifying Point Tester LLTT-A20

Solidifying Point Tester LLTT-A20

Temperature controlling accuracy± 0.5 °C
Refrigeration systemNew-type refrigeration compressor

Open Cup Flash Point Tester

Open Cup Flash Point Tester LOFP-A10

Open Cup Flash Point Tester LOFP-A10

Thermometer0 ℃ ~ 360 °C
Scale Division1 °C
Automatic COC Flash & Fire Point Tester LOFP-B10

Automatic COC Flash & Fire Point Tester LOFP-B10

Cleveland Open Cup Flash Point Tester LOFP-A11

Cleveland Open Cup Flash Point Tester LOFP-A11

Thermometer6 ℃ ~ 400 ℃
Scale Division2 °C
Spout Aperture0.6 ~ 0.8 mm
Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Oxidation Stability Tester

Gasoline Oxidation Stability Tester LOST-D13

Gasoline Oxidation Stability Tester LOST-D13

TypeCompact; Desktop
DesignIntegrated
BathMetal bath (without water usage)
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

Samples2
Oil bath cubage30 L
Oxidation Stability Tester (Lubricating Grease) LOST-D20

Oxidation Stability Tester (Lubricating Grease) LOST-D20

Temperature RangeAmbient to 150℃
Temperature Precision± 0.1°C
Test Unit2 units
Distillate Fuel Oil Oxidation Stability Tester LOST-D12

Distillate Fuel Oil Oxidation Stability Tester LOST-D12

Samples8
Temperature100 ℃
Transformer Oil Oxidation Stability Tester LOST-D11

Transformer Oil Oxidation Stability Tester LOST-D11

Samples6

Oxygen Bomb Calorimeter

Oxygen Bomb Calorimeter LBC-C20

Oxygen Bomb Calorimeter LBC-C20

Heat capacity14000 ~ 15000 J / K
Temperature measurement range10 ~ 35 ℃
Oxygen Bomb Calorimeter LBC-C22

Oxygen Bomb Calorimeter LBC-C22

Temperature measurement range10 ~ 35 ℃
Oxygen Bomb Calorimeter LBC-C21

Oxygen Bomb Calorimeter LBC-C21

Temperature controlling range10 ℃ ~ 35 ℃

Residue Carbon

Carbon Residue Tester (Ramsbottom) LRCT-B20

Carbon Residue Tester (Ramsbottom) LRCT-B20

Coking furnaceMetal furnace
Heating modeElectric heating
Test unit5 units
Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

Carbon Residue Tester (Digital Temperature Controlled Electric Furnace Methods) LRCT-B11

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

Carbon Residue Tester (CONRADSON METHODS) LRCT-B10

Porcelain crucible30 ml
Inner iron crucible75 ml
Outer iron crucible190 ml

Rotational Viscometer

Rotational Viscometer LRV-A10

Rotational Viscometer LRV-A10

Viscosity measurement range10 ~ 2000000 MPa•s
Ambient temperature5 °C ~ 35 °C
Ambient humidityNot more than 80 %

Rust and Corrosion Tester

Lubricating Oil Rust Characteristics Tester LRCT-A11

Lubricating Oil Rust Characteristics Tester LRCT-A11

Sample hole4 pieces
Speed of stirring motor1400 rpm
Speed for sample stirring1000 ± 50 rpm
Copper Strip Corrosion Tester LRCT-A13

Copper Strip Corrosion Tester LRCT-A13

Sample hole4 pieces
Sample quantity4 to 12 pieces
Ambient temperatureRoom temperature to 35 °C
Rust Characteristics and Corrosion Tester LRCT-A12

Rust Characteristics and Corrosion Tester LRCT-A12

Sample hole4 pieces
Ambient temperatureRoom temperature to 35°C
Temperature controlling range0 to 100°C
Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

Liquefied Petroleum Gas Copper Corrosion Tester LRCT-A10

Sample hole2 pieces
Speed of stirring motor1400 rpm
Ambient temperature10 to 35°C

Sulphur Content Tester

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

Dark Petroleum Products Sulphur Content Tester (Tubular Oven Method) LST-A11

Air flow rateNot less than 150 L / h
Max. Preset time99 min 59 s (100 min)
Chamber diameter of ovenΦ22 mm
X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

Vapor Pressure

Vapor Pressure Tester (REID METHOD)  LVPT-C10

Vapor Pressure Tester (REID METHOD) LVPT-C10

Operation temperature of water bathRT ~ 90 °C
Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

Petroleum Products Vapor Pressure Tester(REID METHODS) LVPT-C11

Test bombTwo samples or a group of parallel samples
Bath temperature37.8 °C

Water Content Tester

Coulometric Karl Fischer Titrator LWT-A30

Coulometric Karl Fischer Titrator LWT-A30

Ambient Temperature10°C to 35°C
Measurement Range0 to 100 mg
Resolution0.1 µg
Water Content Tester LWT-A11

Water Content Tester LWT-A11

Ambient Temperature Range≤ 35°C
Relative Humidity≤ 85%
Water Content Tester LWT-A10

Water Content Tester LWT-A10

Ambient Temperature Range≤ 35°C
Relative Humidity≤ 85%
Coulometric Karl Fischer Titrator LWT-A31

Coulometric Karl Fischer Titrator LWT-A31

Maximum current400 mA
Measurement range3 µg to 9999.9 µg
Resolution0.1 µg
Crude Petroleum Water Content Tester LWT-B10

Crude Petroleum Water Content Tester LWT-B10

Ambient Temperature Range-10 to 35°C
Relative Humidity≤85%
Distillation Flask1000 ml

Automatic Tag Closed Flash Point Tester

Automatic Tag Closed Flash Point Tester LACF-A10

Automatic Tag Closed Flash Point Tester LACF-A10

Experimental temperature range-50 to 70°C
Test sample volume50 ml
Ambient temperature range10 to 40°C

Specific Gravity Tester

Specific Gravity Tester LSGT-A10

Specific Gravity Tester LSGT-A10

Vessel Volume 4000 ml × 2
Power of Vacuum pump160 W
Negative power3.7 kPa(27.75 mmHg)

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10

Automatic Dielectric Tester LADT-A10

Capacity2.0 kVA
Speed of voltage increase2 k V/ s
Voltage inspection accuracy0.01

Automatic Softening Point Tester

Automatic Softening Point Tester LSPT-A10

Automatic Softening Point Tester LSPT-A10

Measurement range32 ℃ to 160 ℃
Ambient temperature35 °C
Temperature resolution0.01 ℃

Automatic Thermogravimetric Analyzer

Automatic Thermogravimetric Analyzer LTGA-A10

Automatic Thermogravimetric Analyzer LTGA-A10

 Temperature rangeRoom temperature to 1000 ºC
Temperature resolution0.1 ºC
Temperature fluctuation±0.1 ºC

Penetrometer

Penetrometer LMPT-A12

Penetrometer LMPT-A12

Penetrometer
Measurement range: 0 to 600 penetration scale
Timing controller: 5 sec or 60 sec
Time accuracy: ± 0.1 seconds
Resolution: 0.1 penetration
Penetration accuracy: ± 1 penetration
Weight of standard needle: 2.5 ± 0.05 g
Dimensions (W × L × H): 700 × 400 × 750 mm
Weight: 30 kg
Circulatory Water Bath
Bath volume: 3.5 L
Temperature range: 5 °C to 60 °C
Temperature accuracy: ± 0.1 °C
Circulatory water quantity: 3 L/minute
Pump Lift: 2 m
Power consumption: 1200 W
Power supply: AC 220V ± 10 %, 50 Hz
Dimensions (W × L × H): 600 × 400 × 650 mm
Weight: 40 kg
Penetrometer LMPT-A10

Penetrometer LMPT-A10

Measurement range0 to 600 penetration scale
Timing controller5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy± 0.1 seconds
Penetrometer LMPT-A13

Penetrometer LMPT-A13

Measurement range0 to 600 penetration scale
Timing range0 sec to 60 sec
Time accuracy error≥ ± 0.1 seconds
Penetrometer LMPT-A11

Penetrometer LMPT-A11

Measurement range0 to 600 penetration scale
Timing controller5 sec or 60 sec
Time accuracy± 0.1 seconds

Foaming Characteristics Tester

Foaming Characteristics Tester LFCT-A10

Foaming Characteristics Tester LFCT-A10

Temperature RangeAmbient to 100°C
Temperature Precision± 0.1°C
Air Flow94 mL ± 5 mL/min, with flowmeters

Ash Content Tester

Ash Content Tester LACT-A10

Ash Content Tester LACT-A10

Electric Muffle Furnace
Controlled temperature: 775 ±25 ℃
Temperature rising time of empty chamber: ≤ 50 min
Furnace temperature uniformity: ≤ 15℃
Internal dimension: 200 × 120 × 80 mm
External dimension: 490 × 490 × 450 mm
Power consumption: 2.5 kW
Power supply: AC 220V ±10%, 50 Hz
Net weight: 35 kg
Temperature controller
Maximum control temperature: 1200 ℃
Dimension: 500 × 300 × 235 mm
Power consumption: 5000 W
Power supply: AC 220±10% V, 50Hz
Net weight: 5 kg
Electric heating plate
Heating power: (1 to 6) grades, continuously adjustable
Temperature: 400℃
Diameter of heating plate: Φ 180 mm
Dimension: 280 × 250 × 90 mm
Power consumption: 2000 W
Power supply: AC 220±10%V, 50Hz

Mercaptan Sulfur Tester

Mercaptan Sulfur Tester LMST-A10

Mercaptan Sulfur Tester LMST-A10

Potential measuring range(0 to ±1999.5) Mv
Intrinsic error0.1 % ±0.5 mV
Input impedanceRi ≥1 × 1012 Ω

Constant Temperature Needle Penetration Tester

Constant Temperature Needle Penetration Tester LTNP-A10

Constant Temperature Needle Penetration Tester LTNP-A10

Measuring range0 to 700 taper degree (digital display table 0-70 mm)
Timing deviceTiming error is less than ±0.1 s
 Resolution0.01 mm