| Measurement range | Room temperature ~ 150°C |
| Stirring speed | 0 ~ 1200 r / min |
| Heating power | 25 W |
| Interior Dimension | 360 × 250 × 545 mm |
| Temperature controlling accuracy | ≤ 0.5 ℃ |
| Temperature controlling range | Room temperature ~ 200 ℃ |
| Power supply for illumination | 5 V |
| Power of motor | 2 kW |
| Samples | 8 |
| Temperature | 100 ℃ |
| Temperature controlling accuracy | 0.1 ℃ |
| Flow meter | 3 ± 0.3 L / H oxygen |
| Samples | 6 |
| Temperature controlling mode | Automatic digital temperature |
| Temperature controlling range | Room temperature ~ 160 °C |
| Temperature controlling accuracy | ± 0.2 °C |
| Samples | 2 |
| Oil bath cubage | 30 L |
| Angle between bomb and water surface | 30 ° |
| Speed of rotary assembly | 100 ± 5 RPM |
| Measuring Range For Aviation Gasoline | 86.0 to 105.0/MON |
| Measuring Range For Gasoline For Motor Vehicles | National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON |
| Measuring Range For Ethanol | E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON |
| Measuring Range For Automobile Diesel Fuels | Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI |
| Measurement item | motor gasoline and diesel |
| measurement unit of octane is ON | 40 to 120 |
| Permissible error of octane | ± 0.5 max |
| Fluctuate range of octane | ± 0.2 max |
| Ambient temperature | 10 °C ~ 40 ℃ |
| Relative humidity | ≤ 80 % |
| Ignition Mode | electron igniter / gas flame |
| Temperature range | Room Temperature ~ 300 ℃ |
| Ambient temperature | ≤ 35 °C |
| Relative humidity | ≤ 85 % |
| Temperature range | 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C |
| Aperture of ignition device | 0.8 mm |
| Ambient temperature | 10 °C ~ 40 °C |
| Relative humidity | ≤ 80 % |
| Measurement Range | Ambient Temperature ~ 250 °C |
| Flash Point | Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C |
| Sample hole | 2 pieces |
| Speed of stirring motor | 1400 rpm |
| Ambient temperature | 10 to 35°C |
| Temperature controlling range | Room Temperature to 100°C |
| Sample hole | 4 pieces |
| Speed of stirring motor | 1400 rpm |
| Speed for sample stirring | 1000 ± 50 rpm |
| Ambient temperature | Room temperature to 35°C |
| Sample hole | 4 pieces |
| Sample quantity | 4 to 12 pieces |
| Ambient temperature | Room temperature to 35 °C |
| Temperature controlling range | Room temperature to 100°C |