Penetrometer LMPT-A13

Penetrometer LMPT-A13 is a fully automatic unit for determining needle penetration of highway bitumen, modified asphalt, as well as liquid petroleum asphalt or residue of emulsified asphalt after evaporation material. It has 0.6 penetration measurement accuracy with stable test repeatability. Automatic drawing and print of nomogram of asphalt penetration with special designed computer drawing software and data accurate reading technology. Consists of automatic lifting device for penetration measurement. It is ideally used for petroleum, emulsified asphalt and highway bitumen, etc.

Measurement range 0 to 600 penetration scale
Timing range 0 sec to 60 sec
Time accuracy error ≥ ± 0.1 seconds
Resolution 0.1 penetration
Power consumption 200 W
Power supply AC 220 V ± 10 %, 50 Hz
Needle diameter 50 mm
Sample container (D × H) 55 mm × 35 mm
Dimensions (L × W × H) 260 × 400 × 600 mm
Standard weight 50 g
Weight of standard needle 2.5 ± 0.05 g
Net Weight 15 kg
  • Measurement accuracy reaches up to 0.6 penetrations
  • Equipped with high resolution capacitance touch screen
  • Installed specific computer drawing software and data accurate reading technology
  • Automatic draw and printing of nomogram of asphalt penetration
  • Equipped with automatic lifting device
  • Stable test repeatability with new detection unit

Widely used for determining needle penetration of highway bitumen, modified asphalt, as well as liquid petroleum asphalt or residue of emulsified asphalt after evaporation.

Penetrometer
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.1 penetration
Penetration accuracy ± 1 penetration
Weight of standard needle 2.5 ± 0.05 g
Dimensions (W × L × H) 700 × 400 × 750 mm
Weight 30 kg
Circulatory Water Bath
Bath volume 3.5 L
Temperature range 5 °C to 60 °C
Temperature accuracy ± 0.1 °C
Circulatory water quantity 3 L/minute
Pump Lift 2 m
Power consumption 1200 W
Power supply AC 220V ± 10 %, 50 Hz
Dimensions (W × L × H) 600 × 400 × 650 mm
Weight 40 kg
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Measurement range 0 to 600 penetration scale
Timing controller 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Dimension 390 x 260 x 590 mm
Total power consumption ≤ 1200 W
Power supply AC 220 V ± 10 %, 50 Hz
Heating power of water bath 1000 W
Power supply AC 220 V ± 5 % , 50Hz
Measurement range 0 ~ 75 kV
Voltage rising rate 3 kV ± 10 % / s
Distance between electrodes 2.5 mm
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature (-35) ℃ ± 1 ℃
Evaporation temperature 35 ℃ ± 1 ℃
Viscosity measurement range 10 ~ 2000000 MPa•s
Ambient temperature 5 °C ~ 35 °C
Ambient humidity Not more than 80 %
Spindles Four spindles of No.1 ~ 4
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Measuring range 0 to 700 taper degree (digital display table 0-70 mm)
Timing device Timing error is less than ±0.1 s
 Resolution 0.01 mm
Needle insertion accuracy ±1 cone insertion degree