Open Cup Flash Point Tester LOFP-A10

Labtron LOFP-A10 is designed with higher precision and perfection to meet its wide range of applications. It is incorporated with advanced and reasonable temperature control features.

Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Spout Aperture
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale
Temperature Measurement- Repeatability
Temperature Measurement- Reproducibility
Temperature Measurement- Resolution
Test accuracy
Reappearance
Graduation
Outer Crucible-Material Carbon structural steel
Outer Crucible-Diameter Of Upper Opening Φ100 ± 5 mm
Outer Crucible-Height 50 ± 5 mm
Outer Crucible-Diameter Of Bottom Φ56 ± 2 mm
Inner Crucible-Material Carbon structural steel
Inner Crucible-Diameter Of Upper Opening Φ64 ± 1 mm
Inner Crucible-Height 47 ± 1 mm
Inner Crucible-Diameter Of Bottom Φ38± 1 mm
Inner Crucible-Scale Line 12mm away from the rim of upper opening and 18mm away from the rim of upper opening
Precision
Gas Tube Φ0.8 ~ Φ1 mm
Flame 3 to 4 mm
Heater Heated by an electric furnace
Heating Power 1000W
Dimensions 410 x 360 x 240 mm
Power Consumption ≤ 1100 W
Power Supply AC 220 V ± 10 %, 50Hz
=#REF!
  • Adjustable heating power
  • Electric current meter to display power
  • Tiny desktop structure
  • Easy to operate

Used to determine the flash point and fire point of lubricating oil and dark petroleum products

Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Ambient Temperature 10 ℃ ~ 40 °C
Relative Humidity ≤ 80 %
Temperature Measurement- Full Scale Ambient temperature to 300 °C
Temperature Measurement- Repeatability ≤ 8 °C
Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Power of motor 2 kW
Temperature Range Ambient to 100°C
Temperature Precision ± 0.1°C
Air Flow 94 mL ± 5 mL/min, with flowmeters
Timing Unit 0 to 99 min 59 s, resolution 1 s
Sample hole 4 pieces
Sample quantity 4 to 12 pieces
Ambient temperature Room temperature to 35 °C
Temperature controlling range Room temperature to 100°C
Sample hole 2 pieces
Speed of stirring motor 1400 rpm
Ambient temperature 10 to 35°C
Temperature controlling range Room Temperature to 100°C
Sample hole 4 pieces
Speed of stirring motor 1400 rpm
Speed for sample stirring 1000 ± 50 rpm
Ambient temperature Room temperature to 35°C
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01
Breakdown sensitivity < 0.1 kV
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2