Open Cup Flash Point Tester LOFP-A10

Labtron LOFP-A10 is designed with higher precision and perfection to meet its wide range of applications. It is incorporated with advanced and reasonable temperature control features.

Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Spout Aperture
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale
Temperature Measurement- Repeatability
Temperature Measurement- Reproducibility
Temperature Measurement- Resolution
Test accuracy
Reappearance
Graduation
Outer Crucible-Material Carbon structural steel
Outer Crucible-Diameter Of Upper Opening Φ100 ± 5 mm
Outer Crucible-Height 50 ± 5 mm
Outer Crucible-Diameter Of Bottom Φ56 ± 2 mm
Inner Crucible-Material Carbon structural steel
Inner Crucible-Diameter Of Upper Opening Φ64 ± 1 mm
Inner Crucible-Height 47 ± 1 mm
Inner Crucible-Diameter Of Bottom Φ38± 1 mm
Inner Crucible-Scale Line 12mm away from the rim of upper opening and 18mm away from the rim of upper opening
Precision
Gas Tube Φ0.8 ~ Φ1 mm
Flame 3 to 4 mm
Heater Heated by an electric furnace
Heating Power 1000W
Dimensions 410 x 360 x 240 mm
Power Consumption ≤ 1100 W
Power Supply AC 220 V ± 10 %, 50Hz
=#REF!
  • Adjustable heating power
  • Electric current meter to display power
  • Tiny desktop structure
  • Easy to operate

Used to determine the flash point and fire point of lubricating oil and dark petroleum products

Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Ambient Temperature 10 ℃ ~ 40 °C
Relative Humidity ≤ 80 %
Temperature Measurement- Full Scale Ambient temperature to 300 °C
Temperature Measurement- Repeatability ≤ 8 °C
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
 Temperature range Room temperature to 1000 ºC
Temperature resolution 0.1 ºC
Temperature fluctuation ±0.1 ºC
Heating rate 1 ~ 80 ºC / min
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C