Mechanical Impurity Tester (Weight Method) LMIT-A21

Labtron LMIT-A21 Mechanical Impurity Tester is manufactured with digital temperature controller and motor. The instrument is designed as per “Test Methods for Mechanical Impurity in Petroleum Products and Additive (Weight Methods). We meticulously designed it for accuracy and efficiency.

Light source
Temperature of grinding milk white light bulb
Light hole( Φ14)
Color comparing tube
Dimension 390 x 260 x 590 mm
Non-colorful flat bottom glass tube
Observation lens
Total power consumption ≤ 1200 W
Power supply AC 220 V ± 10 %, 50 Hz
Heating power of water bath 1000 W
Relative humidity ≤ 85 %
Ambient temperature ≤ 35 °C
Temperature display mode of water bath Digitally displayed by a LED
Temperature controlling range in water bath RT to 90 °C
Temperature controlling accuracy in water bath: ± 1 °C
Temperature controlling range in funnel RT to 90 °C
Temperature display mode of funnel Digitally displayed by a LED
Temperature controlling accuracy in funnel ± 2 °C
Controlling case (L × W × H) 390 × 260 × 590 mm
Water bath (L × W × H) 90 × 290 × 370 mm
Cooling bath temperature
Evaporation temperature
Flow rate
Timing range of timer
Measurement range
Voltage rising rate
Distance between electrodes
Output power
  • Advantage of glass vessels, water bath, funnel, suction pump, motor and digital temperature controller.
  • Small size, rapid heating rate and easy installation
  • Save operation time and solvent
  • Desktop structure

It is mainly used in petroleum, chemical, research and development industry.

Light source 220 V, 100 W
Temperature of grinding milk white light bulb 2750 ± 50 K
Light hole( Φ14) 26 pieces
Color comparing tube Φ32 mm
Power supply AC 220 V ± 5 % , 50Hz
Measurement range 0 ~ 75 kV
Voltage rising rate 3 kV ± 10 % / s
Distance between electrodes 2.5 mm
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature (-35) ℃ ± 1 ℃
Evaporation temperature 35 ℃ ± 1 ℃
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Total power consumption ≤ 1200 W
Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Measuring range 0 to 700 taper degree (digital display table 0-70 mm)
Timing device Timing error is less than ±0.1 s
 Resolution 0.01 mm
Needle insertion accuracy ±1 cone insertion degree
Sample hole 4 pieces
Speed of stirring motor 1400 rpm
Speed for sample stirring 1000 ± 50 rpm
Ambient temperature Room temperature to 35°C
Sample hole 4 pieces
Sample quantity 4 to 12 pieces
Ambient temperature Room temperature to 35 °C
Temperature controlling range Room temperature to 100°C
Sample hole 2 pieces
Speed of stirring motor 1400 rpm
Ambient temperature 10 to 35°C
Temperature controlling range Room Temperature to 100°C
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI