Mechanical Impurity Tester (Weight Method) LMIT-A21

Labtron LMIT-A21 Mechanical Impurity Tester is manufactured with digital temperature controller and motor. The instrument is designed as per “Test Methods for Mechanical Impurity in Petroleum Products and Additive (Weight Methods). We meticulously designed it for accuracy and efficiency.

Light source
Temperature of grinding milk white light bulb
Light hole( Φ14)
Color comparing tube
Dimension 390 x 260 x 590 mm
Non-colorful flat bottom glass tube
Observation lens
Total power consumption ≤ 1200 W
Power supply AC 220 V ± 10 %, 50 Hz
Heating power of water bath 1000 W
Relative humidity ≤ 85 %
Ambient temperature ≤ 35 °C
Temperature display mode of water bath Digitally displayed by a LED
Temperature controlling range in water bath RT to 90 °C
Temperature controlling accuracy in water bath: ± 1 °C
Temperature controlling range in funnel RT to 90 °C
Temperature display mode of funnel Digitally displayed by a LED
Temperature controlling accuracy in funnel ± 2 °C
Controlling case (L × W × H) 390 × 260 × 590 mm
Water bath (L × W × H) 90 × 290 × 370 mm
Cooling bath temperature
Evaporation temperature
Flow rate
Timing range of timer
Measurement range
Voltage rising rate
Distance between electrodes
Output power
  • Advantage of glass vessels, water bath, funnel, suction pump, motor and digital temperature controller.
  • Small size, rapid heating rate and easy installation
  • Save operation time and solvent
  • Desktop structure

It is mainly used in petroleum, chemical, research and development industry.

Light source 220 V, 100 W
Temperature of grinding milk white light bulb 2750 ± 50 K
Light hole( Φ14) 26 pieces
Color comparing tube Φ32 mm
Power supply AC 220 V ± 5 % , 50Hz
Measurement range 0 ~ 75 kV
Voltage rising rate 3 kV ± 10 % / s
Distance between electrodes 2.5 mm
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature (-35) ℃ ± 1 ℃
Evaporation temperature 35 ℃ ± 1 ℃
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Measuring range 0 to 700 taper degree (digital display table 0-70 mm)
Timing device Timing error is less than ±0.1 s
 Resolution 0.01 mm
Needle insertion accuracy ±1 cone insertion degree
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Interior Dimension 360 × 250 × 545 mm
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Power of motor 2 kW
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01
Breakdown sensitivity < 0.1 kV