Water Content Tester LWT-A10

Water Content Tester LWT-A10 is fabricated to determine water content in petroleum products and grease according to ASTM D95 (Test Methods for Water Content of Petroleum Products) and ASTM D7303 (Test Methods for Water Content in the Lubricating grease).

Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Distillation Flask
Receiver
Condenser
Heating Unit
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Dimension (exclusive of test vessels)
Dimension (Inclusive of test vessels)
Dimension 580 × 350 × 300 mm
Power Supply AC 200 ± 10 % V, 50 Hz
  • Bidirectional Silicon Controlled Rectifier
  • Ambient Temperature is less than 35°C
  • Relative Humidity is less than 85%
  • Less power consumption

It is used to determine water content in crude oil, refined petroleum products, fuels, biofuels, lubricants, chemicals, and other products 

Maximum current 400 mA
Measurement range 3 µg to 9999.9 µg
Resolution 0.1 µg
Precision 1 ± 2 µg (3µg H<sub>2</sub>O to 20µg H<sub>2</sub>O)
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Ambient Temperature Range -10 to 35°C
Relative Humidity ≤85%
Distillation Flask 1000 ml
Receiver 5 ml, with 0.05 ml graduation
Vessel Volume  4000 ml × 2
Power of Vacuum pump 160 W
Negative power 3.7 kPa(27.75 mmHg)
Power of shaking machine 30 W
Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Samples 6
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Samples 2
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Beaker quantity 600 ml
Ambient temperature (-10) °C ~ 40 °C
Relative humidity ≤ 85 %
Thermometer Measurement range (-5) °C ~ 300 °C
Ambient temperature ≤ 35 ℃
Relative humidity ≤ 85 %
Heating power of electric furnace 250 W × 2
Total power consumption ≤ 700 W