| Ambient temperature | Room temperature to 35 °C |
| Relative humidity | ≤ 85 % |
| Temperature controlling range | Room temperature to 99.9 °C |
| Temperature controlling accuracy | ± 1 °C |
| Ambient temperature | Room temperature to 35 °C |
| Relative humidity | ≤ 85 % |
| Timing range | 1 s to 9 min 59 s |
| Temperature controlling range | Room temperature to 99.9 °C |
| Graduated Flask | 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials) |
| Standard Water Value | 51 ± 1 s |
| Temperature Range | 0 ~ 100 °C |
| Ambient Temperature | 10 °C ~ 40 °C |
| Graduated Flask | 200 ± 0.2 ml |
| Standard Water Value | 51 ± 1 s |
| Temperature Range | 0 ~ 100 °C |
| Temperature Controlling Accuracy | ± 0.2 °C |
| Graduated Flask | 100 ml |
| Standard Water Value | 51 ± 1 s |
| Temperature Range | 0 ~ 100 °C |
| Temperature Controlling Accuracy | ± 0.1 °C |
| Measuring Range For Aviation Gasoline | 86.0 to 105.0/MON |
| Measuring Range For Gasoline For Motor Vehicles | National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON |
| Measuring Range For Ethanol | E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON |
| Measuring Range For Automobile Diesel Fuels | Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI |
| Measurement item | motor gasoline and diesel |
| measurement unit of octane is ON | 40 to 120 |
| Permissible error of octane | ± 0.5 max |
| Fluctuate range of octane | ± 0.2 max |
| Samples | 6 |
| Temperature controlling mode | Automatic digital temperature |
| Temperature controlling range | Room temperature ~ 160 °C |
| Temperature controlling accuracy | ± 0.2 °C |
| Samples | 8 |
| Temperature | 100 ℃ |
| Temperature controlling accuracy | 0.1 ℃ |
| Flow meter | 3 ± 0.3 L / H oxygen |
| Samples | 2 |
| Oil bath cubage | 30 L |
| Angle between bomb and water surface | 30 ° |
| Speed of rotary assembly | 100 ± 5 RPM |
| Ambient temperature | (-10) °C ~ 35 °C |
| Relative humidity | ≤ 85 % |
| Capillary viscometer | 11 pieces |
| Stirring motor | 6 W, 1200 rpm |
| Ambient temperature | (-10) °C ~ 35 °C |
| Relative humidity | ≤ 85 % |
| Capillary viscometer | 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group |
| Stirring motor | 6 W, 1200 rpm |
| Ambient temperature | (-10) °C ~ 35 °C |
| Relative humidity | ≤ 85 % |
| Capillary viscometer | 11 pieces |
| Stirring motor | 6 W, 1200 rpm |