Kinematics Viscometer LKV-A13

Our LKV-A13 is a double layered, desktop structured Kinematic Viscometer which is designed as per ASTM D2171 / D2171M - 10 “Asphalt Kinematic Viscosity Test (Capillary Viscometer Methods”.

Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Sample quantity 3 piece at the same time
Bath temperature Ambient temperature ~ 180.0 °C
Measurement range 100 ~ 150 °C or 150 ~ 200 °C
Bath cubage 23 L
Temperature controlling range
Temperature controlling accuracy ± 0.1 °C
Illumination
Constant temperature bath
Timing range
Barometric
Timing accuracy
Timing device
Temperature sensor
Inner capillary viscometer diameters 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm
Mercury thermometer scale division 0.1 °C
  • Maximum heating temperature can reach upto135 ℃ (or 180 ℃)
  • High temperature resistant glass bath
  • Electric stirring motor
  • High precision digital temperature controller

It is used in the fields of petroleum & its products industries, research and development department.

Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Capillary viscometer 13 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature 15 to 35°C
Relative humidity ≤ 85%
Capillary viscometer 6 capillary Pinkevitch viscometer tubes
Stirring motor 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature 0 ~ 40 ºC
Relative humidity 20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy ± 0.1 °C
Timing range 0.0 s ~ 9999.9 s
Samples 6
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Samples 2
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Viscosity measurement range 10 ~ 2000000 MPa•s
Ambient temperature 5 °C ~ 35 °C
Ambient humidity Not more than 80 %
Spindles Four spindles of No.1 ~ 4
Operation temperature of water bath RT ~ 90 °C
Temperature controlling accuracy ± 0.1 °C
Dimensions 550 × 520 × 102 mm
Pressure meter accuracy ± 0.4 % kPa
Test bomb Two samples or a group of parallel samples
Bath temperature 37.8 °C
Temperature controlling accuracy 0.1 °C
Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature (-35) ℃ ± 1 ℃
Evaporation temperature 35 ℃ ± 1 ℃
Power supply AC 220 V ± 5 % , 50Hz
Measurement range 0 ~ 75 kV
Voltage rising rate 3 kV ± 10 % / s
Distance between electrodes 2.5 mm
Dimension 390 x 260 x 590 mm
Total power consumption ≤ 1200 W
Power supply AC 220 V ± 10 %, 50 Hz
Heating power of water bath 1000 W
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI