Distillation Tester Front Type LDT-A14

Distillation Tester Front Type LDT-A14 is a desktop structure model with adjustable heating power. It is designed according to (Test Methods for Distillation Characteristics of Petroleum Products at Barometric Pressure) as per ASTM D86.

Distillation flask 125 mL
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Division value 1℃
Receiving cylinder 100 ml
Scale division 1 ml
Dimension 620 × 510 × 620 mm
Heating power system 1000 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Desktop structure
  • Flexible and convenient to operatebr/>
  • Special heating furnace to ensure the safety measurementbr/>
  • Adjustable heating powerbr/>
  • Lifting device for easy operation

It is used to determine distillation characteristics of natural gasoline, vehicle gasoline, aviation gasoline, jet fuels, naphtha, diesel oil and similar petroleum products.

Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Graduated flasks 100 ml
Scale division of graduated flask 1 ml
Outer diameter of distillation flask φ65
Refrigeration tube φ14
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Graduated flasks 100 ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Ambient temperature 5 °C to 35 ℃
Relative humidity ≤ 85 %
Cubage of buffer vessel 1000 ml
Max. Residual pressure ≤ 2 mm Hg
Graduated flasks 10 ml and 100 ml
Scale division of graduated flask 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Graduated flasks 100 ml
Distillation flask 125 mL
Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Vessel Volume  4000 ml × 2
Power of Vacuum pump 160 W
Negative power 3.7 kPa(27.75 mmHg)
Power of shaking machine 30 W
Experimental temperature range -50 to 70°C
Test sample volume 50 ml
Ambient temperature range 10 to 40°C
Humidity ≤ 85%
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Total power consumption ≤ 1200 W
Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C