Distillation Tester Front Type LDT-A14

Distillation Tester Front Type LDT-A14 is a desktop structure model with adjustable heating power. It is designed according to (Test Methods for Distillation Characteristics of Petroleum Products at Barometric Pressure) as per ASTM D86.

Distillation flask 125 mL
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Division value 1℃
Receiving cylinder 100 ml
Scale division 1 ml
Dimension 620 × 510 × 620 mm
Heating power system 1000 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Desktop structure
  • Flexible and convenient to operatebr/>
  • Special heating furnace to ensure the safety measurementbr/>
  • Adjustable heating powerbr/>
  • Lifting device for easy operation

It is used to determine distillation characteristics of natural gasoline, vehicle gasoline, aviation gasoline, jet fuels, naphtha, diesel oil and similar petroleum products.

Ambient temperature 5 °C to 35 ℃
Relative humidity ≤ 85 %
Cubage of buffer vessel 1000 ml
Max. Residual pressure ≤ 2 mm Hg
Graduated flasks 100 ml
Distillation flask 125 mL
Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Graduated flasks 100 ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Graduated flasks 100 ml
Scale division of graduated flask 1 ml
Outer diameter of distillation flask φ65
Refrigeration tube φ14
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Graduated flasks 10 ml and 100 ml
Scale division of graduated flask 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Samples 8
Temperature 100 ℃
Temperature controlling accuracy 0.1 ℃
Flow meter 3 ± 0.3 L / H oxygen
Samples 6
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Samples 2
Oil bath cubage 30 L
Angle between bomb and water surface 30 °
Speed of rotary assembly 100 ± 5 RPM
Potential measuring range (0 to ±1999.5) Mv
Intrinsic error 0.1 % ±0.5 mV
Input impedance Ri ≥1 × 1012 Ω
Burette capacity 10 mL
Test bomb Two samples or a group of parallel samples
Bath temperature 37.8 °C
Temperature controlling accuracy 0.1 °C
Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm
Operation temperature of water bath RT ~ 90 °C
Temperature controlling accuracy ± 0.1 °C
Dimensions 550 × 520 × 102 mm
Pressure meter accuracy ± 0.4 % kPa
Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %