Kinematics Viscometer LKV-A10

Kinematics Viscometer LKV-A10 is designed with hard glass bath and electric stirring device with 1200 rpm stirring motor. Designed as per ASTM D445 standard configuration, features ambient to 100°C of temperature range and 0 to 9999.9 s of time range. Compact design with RTD PT100 sensor for uniform bath temperature and 6 capillary Pinkevitch viscometer tubes, it is an ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature.

Ambient temperature 15 to 35°C
Relative humidity ≤ 85%
Capillary viscometer 6 capillary Pinkevitch viscometer tubes
Stirring motor 1200 rpm
Temperature range Ambient to 100°C
Temperature accuracy ±0.1℃
Time range 0 to 9999.9 s
Temperature sensor RTD PT100
Capillary viscometer diameter 0.6 mm, 0.8 mm, 1mm, 1.2 mm, 1.5 mm, 2 mm
Bath capacity 12 L
Bath size Φ255×240 mm
Dimension (W×D×H) 500×310×500 mm
Net weight 11.5 kg
  • Hard glass bath, allow personnel to observe liquid flow
  • Electric stirring device with 1200 rpm stirring motor
  • Ambient to 100°C of temperature range and 0 to 9999.9 s of time range
  • RTD PT100 sensor for uniform bath temperature
  • 6 capillary Pinkevitch viscometer tubes with different inner diameters
  • Designed as per ASTM D445 standard configuration
  • An ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature

Kinematics Viscometer is used to measure flow times for a fixed volume of fuel to flow under gravity through a capillary of the viscometer across the fields of petroleum and its products industries, research and development department etc.

Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature 0 ~ 40 ºC
Relative humidity 20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy ± 0.1 °C
Timing range 0.0 s ~ 9999.9 s
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Capillary viscometer 13 pieces
Stirring motor 6 W, 1200 rpm
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Test bomb Two samples or a group of parallel samples
Bath temperature 37.8 °C
Temperature controlling accuracy 0.1 °C
Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm
Operation temperature of water bath RT ~ 90 °C
Temperature controlling accuracy ± 0.1 °C
Dimensions 550 × 520 × 102 mm
Pressure meter accuracy ± 0.4 % kPa
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C