Ash Content Tester LACT-A10

Ash Content Tester LACT-A10 is the device composed of muffle furnace, temperature controller and electric heating plate. It is small size and needs less land with special fire-resistant material and heating components. The heating time is short and it has a long lifetime. It used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and petroleum products.

Electric Muffle Furnace
  • Controlled temperature: 775 ±25 ℃
  • Temperature rising time of empty chamber: ≤ 50 min
  • Furnace temperature uniformity: ≤ 15℃
  • Internal dimension: 200 × 120 × 80 mm
  • External dimension: 490 × 490 × 450 mm
  • Power consumption: 2.5 kW
  • Power supply: AC 220V ±10%, 50 Hz
  • Net weight: 35 kg
Temperature controller
  • Maximum control temperature: 1200 ℃
  • Dimension: 500 × 300 × 235 mm
  • Power consumption: 5000 W
  • Power supply: AC 220±10% V, 50Hz
  • Net weight: 5 kg
Electric heating plate
  • Heating power: (1 to 6) grades, continuously adjustable
  • Temperature: 400℃
  • Diameter of heating plate: Φ 180 mm
  • Dimension: 280 × 250 × 90 mm
  • Power consumption: 2000 W
  • Power supply: AC 220±10%V, 50Hz
  • It is composed of muffle furnace, a temperature controller and electric heating plate
  • Muffle furnace adopts all-in-one structure
  • Equipped with special fire-resistant material and heating components
  • Adjustable LED and designed with temperature controller
  • The overshoot is small and temperature control is stable
  • Material used cold-roll steel sheet of outer shell furnace
  • Good anti-corrosion and long life time

Ash Content Tester is used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and residual fuels, gas turbine fuels, crude oils, lubricating oils, waxes, and other petroleum products, in which any ash-forming materials present are normally considered to be undesirable impurities or contaminants.

Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Evaporation bath type and size Aluminum block bath, φ260 × 130 mm
Holes for testing 3 pieces
Size of holes for testing cylinder φ51 × 70 mm
Flow rate display Flow meter
Bath type Oil bath
Bath capacity 5000 ml ± 50 ml
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Evaporation bath type and size Aluminum bath φ260 × 130 mm
Holes for testing 5 pieces
Size of holes for testing cylinder φ51 × 70 mm
Working temperature 160 ℃ ~ 165℃
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Experimental temperature range -50 to 70°C
Test sample volume 50 ml
Ambient temperature range 10 to 40°C
Humidity ≤ 85%
Ambient temperature ≤ 35 ℃
Relative humidity ≤ 85 %
Heating power of electric furnace 250 W × 2
Total power consumption ≤ 700 W
Beaker quantity 600 ml
Ambient temperature (-10) °C ~ 40 °C
Relative humidity ≤ 85 %
Thermometer Measurement range (-5) °C ~ 300 °C