Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11

Petroleum Oils and Synthetic Fluids Demulsibility Characteristics Tester LDCT-A11 is designed and made as per “Test Methods for Demulsibility Characteristics of Petroleum Oils and Synthetic Fluids” and “Test Methods for Demulsibility Characteristics of Oils in Service” ASTM D1401.

Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Temperature resolution
Stirring speed 1500 ± 15 rpm
Heating power for temperature controlling
Total power consumption
Power supply AC 220 V ± 10 %, 50 Hz
Dimension 740 × 510 × 680 mm
  • LCD display
  • Man-machine conversation interface
  • Automatic stirring and timing
  • Test arm can be moved up and down automatically

It can be widely used in the field of petroleum , chemical industry and scientific research

Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Temperature measurement range 10 ~ 35 ℃
Repeatability error ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb 20 MPa
Operation environment temperature 15 ~ 28 ℃
Heat capacity 14000 ~ 15000 J / K
Temperature measurement range 10 ~ 35 ℃
Repeatability error ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb 20 MPa
Temperature controlling range 10 ℃ ~ 35 ℃
Temperature resolution 0.001 ℃
Mean value of heat capacity 15 kJ / K
Ambient temperature 20 ℃ ± 5 ℃
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature (-35) ℃ ± 1 ℃
Evaporation temperature 35 ℃ ± 1 ℃
Dimension 390 x 260 x 590 mm
Total power consumption ≤ 1200 W
Power supply AC 220 V ± 10 %, 50 Hz
Heating power of water bath 1000 W
Power supply AC 220 V ± 5 % , 50Hz
Measurement range 0 ~ 75 kV
Voltage rising rate 3 kV ± 10 % / s
Distance between electrodes 2.5 mm
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C