Engler Viscometer LEV-A11

Labtron LEV-A11 is designed according to the ASTM D1665 “Test Methods for Engler Viscosity of Petroleum Products” standard. It is devised with digital temperature controller and its chambers are made with stainless steel to avoid corrosion.

Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature
Temperature Controlling Accuracy ± 0.1 °C
Relative Humidity
Timer
Accuracy Of Timer 0.01 s
Heating Power
Dimension 510 x 365 x 290 mm
Power Of Heater 550 W / 220 V
Total Power Consumption
Power Supply
=#REF!
  • PID adjustment
  • High accuracy
  • Digital temperature controller
  • Preset parameters with high temperature controlling accuracy

It is extensively used for pharmaceutics, petroleum, chemical, scientific research etc.

Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Viscosity measurement range 10 ~ 2000000 MPa•s
Ambient temperature 5 °C ~ 35 °C
Ambient humidity Not more than 80 %
Spindles Four spindles of No.1 ~ 4
 Temperature range Room temperature to 1000 ºC
Temperature resolution 0.1 ºC
Temperature fluctuation ±0.1 ºC
Heating rate 1 ~ 80 ºC / min
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
Experimental temperature range -50 to 70°C
Test sample volume 50 ml
Ambient temperature range 10 to 40°C
Humidity ≤ 85%
Coking furnace Metal furnace
Heating mode Electric heating
Test unit 5 units
Temperature range Ambient to 550°C
Bath type Four holes with a furnace
Heating type Electric resistance furnace
Temperature controlling range 0 ~ 520 °C
Temperature controlling accuracy ± 5 °C
Porcelain crucible 30 ml
Inner iron crucible 75 ml
Outer iron crucible 190 ml
Burner Mig Burner