Distillation Tester LDT-A10

Distillation Tester LDT-A10 is a desktop device, automated and can withstand a very high temperature. It is designed according to (Test Methods for Distillation Characteristics of Petroleum Products) as per ASTM D86.

Graduated flasks 10 ml and 100 ml
Scale division of graduated flask 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Thermometer 0 °C ~ 360 °C
Scale division 1 °C
Inner diameter of electric furnace Ф50 mm, Ф30 mm and with a gap
Outer diameter of electric furnace Ф105 mm
Refrigeration tube Made of copper tube of ф16 × 1
Angle between refrigeration tube and water level 15°
Length of refrigeration tube 555 ± 3 mm
Size of refrigeration bath 180 x 100 x 150 mm
Ball diameter of flask Ф69 ± 1 mm
Neck diameter of flask Ф16 ± 1 mm
Angle between branch tube and neck 75° ± 3°
Dimension 790 x 360 x 710 mm
Heating power system 1000 W / 220 V
Total power consumption ≤ 1100 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Alterable heating rate
  • Distillation flask sustains temperature more than 500 °C
  • Two graduated flasks
  • Temperature adjustment circuit

It is used to determine distillate of engine fuel, solvent oil and light petroleum products.

Graduated flasks 100 ml
Scale division of graduated flask 1 ml
Outer diameter of distillation flask φ65
Refrigeration tube φ14
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Distillation flask 125 mL
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Ambient temperature 5 °C to 35 ℃
Relative humidity ≤ 85 %
Cubage of buffer vessel 1000 ml
Max. Residual pressure ≤ 2 mm Hg
Graduated flasks 100 ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Graduated flasks 100 ml
Distillation flask 125 mL
Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01
Breakdown sensitivity < 0.1 kV
Temperature Range Ambient to 100°C
Temperature Precision ± 0.1°C
Air Flow 94 mL ± 5 mL/min, with flowmeters
Timing Unit 0 to 99 min 59 s, resolution 1 s
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Temperature measurement range 10 ~ 35 ℃
Repeatability error ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb 20 MPa
Operation environment temperature 15 ~ 28 ℃
Heat capacity 14000 ~ 15000 J / K
Temperature measurement range 10 ~ 35 ℃
Repeatability error ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb 20 MPa
Temperature controlling range 10 ℃ ~ 35 ℃
Temperature resolution 0.001 ℃
Mean value of heat capacity 15 kJ / K
Ambient temperature 20 ℃ ± 5 ℃
Operation temperature of water bath RT ~ 90 °C
Temperature controlling accuracy ± 0.1 °C
Dimensions 550 × 520 × 102 mm
Pressure meter accuracy ± 0.4 % kPa
Test bomb Two samples or a group of parallel samples
Bath temperature 37.8 °C
Temperature controlling accuracy 0.1 °C
Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm