Distillation Tester LDT-A10

Distillation Tester LDT-A10 is a desktop device, automated and can withstand a very high temperature. It is designed according to (Test Methods for Distillation Characteristics of Petroleum Products) as per ASTM D86.

Graduated flasks 10 ml and 100 ml
Scale division of graduated flask 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Thermometer 0 °C ~ 360 °C
Scale division 1 °C
Inner diameter of electric furnace Ф50 mm, Ф30 mm and with a gap
Outer diameter of electric furnace Ф105 mm
Refrigeration tube Made of copper tube of ф16 × 1
Angle between refrigeration tube and water level 15°
Length of refrigeration tube 555 ± 3 mm
Size of refrigeration bath 180 x 100 x 150 mm
Ball diameter of flask Ф69 ± 1 mm
Neck diameter of flask Ф16 ± 1 mm
Angle between branch tube and neck 75° ± 3°
Dimension 790 x 360 x 710 mm
Heating power system 1000 W / 220 V
Total power consumption ≤ 1100 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Alterable heating rate
  • Distillation flask sustains temperature more than 500 °C
  • Two graduated flasks
  • Temperature adjustment circuit

It is used to determine distillate of engine fuel, solvent oil and light petroleum products.

Graduated flasks 100 ml
Distillation flask 125 mL
Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Graduated flasks 100 ml
Scale division of graduated flask 1 ml
Outer diameter of distillation flask φ65
Refrigeration tube φ14
Ambient temperature 5 °C to 35 ℃
Relative humidity ≤ 85 %
Cubage of buffer vessel 1000 ml
Max. Residual pressure ≤ 2 mm Hg
Distillation flask 125 mL
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Graduated flasks 100 ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01
Breakdown sensitivity < 0.1 kV
Experimental temperature range -50 to 70°C
Test sample volume 50 ml
Ambient temperature range 10 to 40°C
Humidity ≤ 85%
Viscosity measurement range 10 ~ 2000000 MPa•s
Ambient temperature 5 °C ~ 35 °C
Ambient humidity Not more than 80 %
Spindles Four spindles of No.1 ~ 4
Cubage of bath Ф300 × 380 mm
Temperature controlling range 0 °C ~ 100 °C
Temperature controlling accuracy ± 0.2 °C
Temperature sensor Industrial platinum resistance, Pt100
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Total power consumption ≤ 1200 W
Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml