Pour and Cloud Point Tester LLTT-A14

Pour and Cloud Point Tester LLTT-A14 is a concise designed unit, made as per ASTM D97,ASTM D2500, ASTM D5853 Standard Test Method for Pour Point of Petroleum Oils and ASTM D5773, Standard Test Method of Cloud Point of Petroleum Products. Features two cooling bath chambers with temperature controller, ensures fast and high cooling efficiency. Equipped with new type of refrigeration compressor, the temperature of both cooling bath is same with ±1°C precision. With benchtop structure and easy usage, this pour and cloud point tester is suitable to determine pour point and cloud point of petroleum oils.

Chamber quantity 2 chambers
Chamber 01 temperature control Ambient to -51 ℃
Chamber 02 temperature control Ambient to -65 ℃
Temperature precision ±1°C
Ambient temperature ≤ 30°C
Relative humidity ≤ 85%
Refrigeration system New type refrigeration compressor
Power supply AC 220 V± 10%, 50 Hz
Power 1500 W
Dimension (L×W×H) 800×580×400 mm
Weight 32 kg
  • Concise designed unit with benchtop structure
  • Made as per ASTM D97,ASTM D2500, ASTM D5853 Standard Test Method for Pour Point of Petroleum Oils
  • Designed as per ASTM D5773, Standard Test Method of Cloud Point of Petroleum Products
  • Two cooling bath chambers with temperature controller and new type of refrigeration compressor
  • Both cooling bath temperature is same with ±1°C precision
  • Suitable to determine pour point and cloud point of petroleum oils
  • Fast and high cooling efficiency with easy usage

Pour and cloud point tester is used for precise and convenient flow testing of petroleum products, biodiesel fuels, additives and lubricating oils etc.

Ambient temperature ≤ 30 ℃
Refrigeration speed > 40 °C / 10 min
Repeatability for solidifying point ≤ 2 °C
Repeatability for pour point ≤ 3 °C
Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Refrigeration system New-type refrigeration compressor
Controlling temperature of cold trough Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature ≤ 30 ℃
Relative humidity ≤ 85 %
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Ambient temperature ≤ 30 ℃
Temperature controlling accuracy ± 0.5 °C
Refrigeration system New-type refrigeration compressor
Cold trough One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough Room temperature ~ (-70) °C
Freezing point range -54°C to 2°C
Cold bath measurement temperature range -70° to 20°C
Temperature controlling accuracy ±0.5°C
Bath liquids stirring Electric
Temperature controlling accuracy ± 0.5 ℃
Refrigeration system New-type refrigeration compressor
Cold trough Two holes in one trough, and same temperature
Ambient temperature ≤ 30 ℃
Capacity 20 L
Temperature range Ambient +5°C to 100°C
Precision ± 0.1℃
Stirring range 1200 r/min
Ambient temperature (-10)℃ ~ 35 ℃
Relative humidity ≤ 85 %
Sample cup Inner diameter 31.0 ~ 32.0 mm
Sample cup Wall thickness 1.0 ~ 1.5 mm
Vessel Volume  4000 ml × 2
Power of Vacuum pump 160 W
Negative power 3.7 kPa(27.75 mmHg)
Power of shaking machine 30 W
Power supply AC 220 V ± 5 % , 50Hz
Measurement range 0 ~ 75 kV
Voltage rising rate 3 kV ± 10 % / s
Distance between electrodes 2.5 mm
Dimension 390 x 260 x 590 mm
Total power consumption ≤ 1200 W
Power supply AC 220 V ± 10 %, 50 Hz
Heating power of water bath 1000 W
Power supply AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature (-35) ℃ ± 1 ℃
Evaporation temperature 35 ℃ ± 1 ℃
Measurement item motor gasoline and diesel
measurement unit of octane is ON 40 to 120
Permissible error of octane ± 0.5 max
Fluctuate range of octane ± 0.2 max
 Measuring Range For Aviation Gasoline 86.0 to 105.0/MON
 Measuring Range For Gasoline For Motor Vehicles National standard: 65.0 to 110.0/RON<br/> National-V standard: 70 to 115.0/RON<br/> Blended gasoline: 75.0 to 120.0/RON<br/> Light gasoline: 50.0 to 85.0 /MON<br/> Isomerized gasoline: 85.0 to 120.0/RON<br/> Arene gasoline: 90.0 to 120.0/RON
 Measuring Range For Ethanol E93: 92.0 to 95.0/RON<br/> E97: 95.0 to 99.0/RON<br/> Judgement: 60.0 to 120.0/RON
Measuring Range For Automobile Diesel Fuels Cetane number: 25 to 75/CN<br/> Cetane index: 20 to 80/CI
Operation temperature of water bath RT ~ 90 °C
Temperature controlling accuracy ± 0.1 °C
Dimensions 550 × 520 × 102 mm
Pressure meter accuracy ± 0.4 % kPa
Test bomb Two samples or a group of parallel samples
Bath temperature 37.8 °C
Temperature controlling accuracy 0.1 °C
Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C