Cleveland Open Cup Flash Point Tester LOFP-A11

Labtron LOFP-A11 is designed with quartz tube heater which is highly efficient and cost effective and used to trace many products. It is designed and made as per ISO 2592, ASTM 92 “Test Methods for Flash and Fire Point of Petroleum Products (Cleveland Open Cup Methods)”.

Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale
Temperature Measurement- Repeatability
Temperature Measurement- Reproducibility
Temperature Measurement- Resolution
Test accuracy
Reappearance
Graduation
Outer Crucible-Material
Outer Crucible-Diameter Of Upper Opening
Outer Crucible-Height
Outer Crucible-Diameter Of Bottom
Inner Crucible-Material
Inner Crucible-Diameter Of Upper Opening
Inner Crucible-Height
Inner Crucible-Diameter Of Bottom
Inner Crucible-Scale Line
Precision
Gas Tube
Flame
Heater
Heating Power
Dimensions 480 x 400 x 300 mm
Power Consumption 0 ~ 600 W
Power Supply AC 220 V ± 10 %, 50 Hz
=#REF!
  • Explosion protective
  • Power can be constantly adjusted
  • Robotically scanning flame application gadget
  • Coal gas as ignition source

It is suitable to determine flash point and fire point of petroleum products having a flash point higher than 79 °C, excepting fuel oils

Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Ambient Temperature 10 ℃ ~ 40 °C
Relative Humidity ≤ 80 %
Temperature Measurement- Full Scale Ambient temperature to 300 °C
Temperature Measurement- Repeatability ≤ 8 °C
Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor 6 W, 1200 rpm
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Capillary viscometer 11 pieces
Stirring motor 6 W, 1200 rpm
Vessel Volume  4000 ml × 2
Power of Vacuum pump 160 W
Negative power 3.7 kPa(27.75 mmHg)
Power of shaking machine 30 W