Cleveland Open Cup Flash Point Tester LOFP-A11

Labtron LOFP-A11 is designed with quartz tube heater which is highly efficient and cost effective and used to trace many products. It is designed and made as per ISO 2592, ASTM 92 “Test Methods for Flash and Fire Point of Petroleum Products (Cleveland Open Cup Methods)”.

Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale
Temperature Measurement- Repeatability
Temperature Measurement- Reproducibility
Temperature Measurement- Resolution
Test accuracy
Reappearance
Graduation
Outer Crucible-Material
Outer Crucible-Diameter Of Upper Opening
Outer Crucible-Height
Outer Crucible-Diameter Of Bottom
Inner Crucible-Material
Inner Crucible-Diameter Of Upper Opening
Inner Crucible-Height
Inner Crucible-Diameter Of Bottom
Inner Crucible-Scale Line
Precision
Gas Tube
Flame
Heater
Heating Power
Dimensions 480 x 400 x 300 mm
Power Consumption 0 ~ 600 W
Power Supply AC 220 V ± 10 %, 50 Hz
=#REF!
  • Explosion protective
  • Power can be constantly adjusted
  • Robotically scanning flame application gadget
  • Coal gas as ignition source

It is suitable to determine flash point and fire point of petroleum products having a flash point higher than 79 °C, excepting fuel oils

Ambient Temperature 10 ℃ ~ 40 °C
Relative Humidity ≤ 80 %
Temperature Measurement- Full Scale Ambient temperature to 300 °C
Temperature Measurement- Repeatability ≤ 8 °C
Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Thermometer 0 ℃ ~ 360 °C
Scale Division 1 °C
Ambient Temperature ≤ 35 °C
Relative Humidity ≤ 85 %
Test bomb Two samples or a group of parallel samples
Bath temperature 37.8 °C
Temperature controlling accuracy 0.1 °C
Dimensions 500 × 560 × 680 mm, 950 × 540 × 720 mm
Operation temperature of water bath RT ~ 90 °C
Temperature controlling accuracy ± 0.1 °C
Dimensions 550 × 520 × 102 mm
Pressure meter accuracy ± 0.4 % kPa
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Measurement range 0 to 600 penetration scale
Timing controller 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Penetrometer
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.1 penetration
Penetration accuracy ± 1 penetration
Weight of standard needle 2.5 ± 0.05 g
Dimensions (W × L × H) 700 × 400 × 750 mm
Weight 30 kg
Circulatory Water Bath
Bath volume 3.5 L
Temperature range 5 °C to 60 °C
Temperature accuracy ± 0.1 °C
Circulatory water quantity 3 L/minute
Pump Lift 2 m
Power consumption 1200 W
Power supply AC 220V ± 10 %, 50 Hz
Dimensions (W × L × H) 600 × 400 × 650 mm
Weight 40 kg
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL
Viscosity measurement range 10 ~ 2000000 MPa•s
Ambient temperature 5 °C ~ 35 °C
Ambient humidity Not more than 80 %
Spindles Four spindles of No.1 ~ 4