X-ray Fluorescence Sulfur in Oil Analyzer LST-A10

Labtron LST-A10 is incorporated with self-diagnostic function and electromagnetic integration. It is designed according to International Standards ASTM D4294 and ASTM D7039 for repeatability and reproducibility.

Air flow rate
Max. Preset time
Chamber diameter of oven
Heating power of oven
Max. Temperature of oven
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Reproducibility < 0.063 (S + 0.6)
Temperature 5 ℃ to 40 ℃
Relative humidity ≤ 85 % (30 ℃)
Power supply AC 220 V ± 20 V, 50 Hz
Rated power 30 W
Dimensions 468 x 368 x 136 mm
Weight 13 kg
  • Microprocessor controller
  • Large screen LCD display
  • Rapid and convenient
  • Save large quantity of test data

It is used to determine mass % of total sulfur in the crude petroleum, petroleum, heavy oil, diesel oil, gasoline and naphtha. It can be used to determine total sulfur content in the products of coal chemical industry, such as primary benzene and other liquid or solid powder samples.

Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Temperature Range Ambient to 100°C
Temperature Precision ± 0.1°C
Air Flow 94 mL ± 5 mL/min, with flowmeters
Timing Unit 0 to 99 min 59 s, resolution 1 s
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W × 2
Sample Determination 2 at a time
Ambient Temperature Range ≤ 35°C
Relative Humidity ≤ 85%
Heating Mantle Cap Power 1000 W
Sample Determination 1 at a time
Ambient Temperature 10°C to 35°C
Measurement Range 0 to 100 mg
Resolution 0.1 µg
Max. Electrolysis Speed 40 µg /s
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Sample quantity 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time 60, 120, 240, 300, and 600 s at random
Measurement range 7 ppm to 5 %
Repeatability < 0.029 (S + 0.6)
Air flow rate Not less than 150 L / h
Max. Preset time 99 min 59 s (100 min)
Chamber diameter of oven Φ22 mm
Heating power of oven 1400 W × 2
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode The outer barrel temperature is constant
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Operation Mode A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Calorimeter type Isoperibol
Oxygen filling Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume 250 ml
Analysis time < 8 min full test process: <10 min