Automatic Distillation Apparatus LADA-A10

Automatic Distillation Apparatus LADA-A10 is a benchtop unit which can automatically determine the distillation range of petroleum products. Test procedures like heating, distillation speed and recording the data are fully automated. Large LCD display and easy to handle operations makes it highly convenient to use. It complies with ASTM D86 and IP123 standards.

Heating power 2 kW
Cooling power 0.5 kW
Steam temperature 0 to 400℃
Oven temperature 0 to 500℃
Refrigeration temperature 0 to 60℃
Refrigeration accuracy ± 1℃
Temperature measurement accuracy ± 0.1℃
Volume accuracy ± 0.1 ml
Power AC 220 V ± 10% 50 Hz
  • 10'' LCD touch screen to view and pre-set several parameters
  • Highly advance level tracking system with American Haydon high-stepping linear motor
  • Imported integral linear ball screw circumferential positioning laser tracker
  • Imported Danfoss (Secop) Compressor
  • Mechanically refrigerated cooling tube and cylinder room
  • Automatic heating control (distillation process): up to 95% sample heating control with controlled flow rate of 4 to 5 ml/min
  • Display shows initial and final boiling point temperature, various % temperature and flow rate
  • Automatic correction of local atmospheric pressure to standard atmospheric pressure
  • Test process is stopped by temperature of steam
  • Results can be stored and printed

It is widely used to determine the distillation range of various petroleum products in laboratories, research institutes and industries.

Graduated flasks 10 ml and 100 ml
Scale division of graduated flask 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature (-10) °C ~ 35 °C
Relative humidity ≤ 85 %
Ambient temperature -10°C to 35°C
Relative humidity ≤ 85 %
Thermometer Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division 0.1 ℃
Graduated flasks 100 ml
Scale division of graduated flask 1ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Ambient temperature 5 °C to 35 ℃
Relative humidity ≤ 85 %
Cubage of buffer vessel 1000 ml
Max. Residual pressure ≤ 2 mm Hg
Distillation flask 125 mL
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Thermometer (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Graduated flasks 100 ml
Distillation flask 125 mL
Ambient temperature ≤ 30 °C
Relative humidity ≤ 85 %
Graduated flasks 100 ml
Distillation flask 125 ml
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Graduated flasks 100 ml
Scale division of graduated flask 1 ml
Outer diameter of distillation flask φ65
Refrigeration tube φ14
Sample hole 2 pieces
Speed of stirring motor 1400 rpm
Ambient temperature 10 to 35°C
Temperature controlling range Room Temperature to 100°C
Sample hole 4 pieces
Sample quantity 4 to 12 pieces
Ambient temperature Room temperature to 35 °C
Temperature controlling range Room temperature to 100°C
Sample hole 4 pieces
Speed of stirring motor 1400 rpm
Speed for sample stirring 1000 ± 50 rpm
Ambient temperature Room temperature to 35°C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Temperature controlling range Room temperature to 99.9 °C
Temperature controlling accuracy ± 1 °C
Ambient temperature Room temperature to 35 °C
Relative humidity ≤ 85 %
Timing range 1 s to 9 min 59 s
Temperature controlling range Room temperature to 99.9 °C
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Total power consumption ≤ 1200 W
Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml