Density Tester LDMT-A10

Labtron LDMT-A10 density tester is simple and compact. The control box adopts humanized design and the control switch adopts light-touch mode. The instrument is designed and made as per ASTM D1298 “Test Methods for Density of Petroleum and Liquid Petroleum Products (Densimeter Methods)”.

Cubage of bath Ф300 × 380 mm
Temperature controlling range 0 °C ~ 100 °C
Temperature controlling accuracy ± 0.2 °C
Temperature sensor Industrial platinum resistance, Pt100
Thermometer Total immersion mercury thermometer
Scale division 0.2 °C
Heating power 700 W; 1000 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Fast control rate and small over-shoot
  • Adopts intelligent LCD temperature controller
  • Unvarying vessel temperature
  • Easy to operate and observe the sample
  • Refrigeration device (Optional)

It is used to determine the density of crude petroleum and liquid petroleum.

Measurement range ≥0.05 mg KOH/g
Potential measurement range 0 to 1800.0 mV
Burette volume 10 mL
Minimum titration volume 0.001 ml
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Ambient temperature (-10 )°C to 35 °C
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Total power consumption ≤ 1200 W
Measurement range 0 to 600 penetration scale
Timing controller 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Penetrometer
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.1 penetration
Penetration accuracy ± 1 penetration
Weight of standard needle 2.5 ± 0.05 g
Dimensions (W × L × H) 700 × 400 × 750 mm
Weight 30 kg
Circulatory Water Bath
Bath volume 3.5 L
Temperature range 5 °C to 60 °C
Temperature accuracy ± 0.1 °C
Circulatory water quantity 3 L/minute
Pump Lift 2 m
Power consumption 1200 W
Power supply AC 220V ± 10 %, 50 Hz
Dimensions (W × L × H) 600 × 400 × 650 mm
Weight 40 kg
Measurement range 0 to 600 penetration scale
Timing controller 5 sec or 60 sec
Time accuracy ± 0.1 seconds
Resolution 0.01 mm
Graduated Flask 200 ± 0.2 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.2 °C
Graduated Flask 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Ambient Temperature 10 °C ~ 40 °C
Graduated Flask 100 ml
Standard Water Value 51 ± 1 s
Temperature Range 0 ~ 100 °C
Temperature Controlling Accuracy ± 0.1 °C
Temperature Range Ambient to 100°C
Temperature Precision ± 0.1°C
Air Flow 94 mL ± 5 mL/min, with flowmeters
Timing Unit 0 to 99 min 59 s, resolution 1 s
Potential measuring range (0 to ±1999.5) Mv
Intrinsic error 0.1 % ±0.5 mV
Input impedance Ri ≥1 × 1012 Ω
Burette capacity 10 mL